상세 보기
경계조건과 형태 기반으로 구성된 5개 와이어웨이시스템의 진동대 실험을 통한 내진성능 검증
- 진수민;
- Han Van Tran;
- 김성찬;
- 신지욱;
- 이기학
초록
This paper presents the results of an experimental seismic investigation performed on prototypes made of a pulley-wireway system with four different boundary conditions and an existing lighting structure support, a one-way system, through a tri-axial shaking table test. The attention of this study focused on evaluating the seismic qualification of the prototypes based on ICC-ES AC 156. In particular, the influence of the mounting position of prototypes at the ceiling, steel frames, walls, and beam or column on the seismic response of the building was also discussed in detail. The seismic performance in terms of acceleration and displacement response was also evaluated by power spectral density-based (PSD), and root mean square-based (RMS), which showed a better seismic response of H-beam frame type than other types of pulley-type wireway system. Finally, it was determined that the newly developed lighting support with the addition of a pulley is capable of dissipating seismic energy more effectively than the previous lighting equipment system.
키워드
- 제목
- 경계조건과 형태 기반으로 구성된 5개 와이어웨이시스템의 진동대 실험을 통한 내진성능 검증
- 제목 (타언어)
- Seismic Performance Evaluation of 5 Different Wireway-pulley System Subjected to Shaking Table Test
- 저자
- 진수민; Han Van Tran; 김성찬; 신지욱; 이기학
- 발행일
- 2021
- 저널명
- 조명.전기설비학회논문지
- 권
- 35
- 호
- 12
- 페이지
- 45 ~ 54