상세 보기
초록
The article focuses on the Temperature characteristics inside single loop oscillating heat pipe (OHPs). In this paper, heat pipe is experimentally studied thereby providing vital information on the parameter dependency of their thermal performance. The impact depiction has been done for the variation of tube model of the device. OHPs are made of copper capillary tubes of outer diameter 6.25 mm, inner diameter 4 mm heated by constant temperature water bath cooled by ambient temperature. Using four types of OHPs of copper capillary tubes length of 1500mm and HP length 650mm inside tubes working fluid is R-22 Pressure 8 bar and mass 34g,32g,28g,16g. The results indicate a strong influence of filling ratio on the performance
키워드
- 제목
- Experimental Investigations on the Temperature Characteristics of Oscillating Heat Pipe with Various Filling Ratio
- 제목 (타언어)
- Experimental Investigations on the Temperature Characteristics of Oscillating Heat Pipe with Various Filling Ratio
- 저자
- 정효민; 정한식; 이광성; Md. Riyad Tanshen; 이태진; 이신일
- 발행일
- 2013
- 저널명
- 동력시스템공학회지
- 권
- 17
- 호
- 6
- 페이지
- 47 ~ 53