상세 보기
A Case of Broncho-Paraspinal Fistula Induced by Metallic Devices: Delayed Complication of Thoracic Spinal Surgery
- Son, Seungnam;
- Kang, Dong-Ho;
- Choi, Dae Seub;
- Choi, Nack-Cheon
WEB OF SCIENCE
5SCOPUS
6초록
We present a case report of a 45-year-old woman with spontaneous pneumocephalus accompanied by pneumorrhachis of the thoracic spine, which is a very rare condition generally associated with trauma and thoracic or spinal surgery. The patient had undergone an operation about 10 years earlier to treat a giant cell tumor of the thoracic spine. During the operation, a metallic device was installed, which destroyed the bronchus and caused the formation of a broncho-paraspinal fistula. This is the suspected cause of her pneumocephalus and pneumorrhachis. To our knowledge, this is a very rare case of pneumocephalus accompanied by pneumorrhachis induced by metallic device, and when considering the length of time after surgery these complications presented are also exceptional.
키워드
- 제목
- A Case of Broncho-Paraspinal Fistula Induced by Metallic Devices: Delayed Complication of Thoracic Spinal Surgery
- 저자
- Son, Seungnam; Kang, Dong-Ho; Choi, Dae Seub; Choi, Nack-Cheon
- 발행일
- 2011-07
- 유형
- Article
- 저널명
- 대한신경외과학회지
- 권
- 50
- 호
- 1
- 페이지
- 64 ~ 67
- 언어
- ENG
- 출판사
- KOREAN NEUROSURGICAL SOC
- 발행국가
- 대한민국
- 분량
- 4 페이지
- ISSN
- E 1598-7876
P 2005-3711