상세 보기
초록
This paper aims to report the experimental study on the axial compressive behavior of tubular stub columns filled with variable concrete strength(fcu=500, 700, 1,000kgf/cm2). Thirty-two specimens were tested to investigate the relationship between concrete strength and the ultimate strength of stub column. The effects of inner concrete on the failure mode, the ultimate strength, initial stiffness and deformation capacity were discussed. Also this paper presents experimental results on the strength and deformation of concrete-filled steel stub columns. Because the strength of concrete filled into the hollow tube was limited less than 500kgf/cm2 in Korean standard. From this experimental study, it was found that the axial strength of CFT column was not proportioned increased with the compressive strength of concrete. Both circular and square stub column specimens filled with the compressive strength of 1000kgf/cm2 concrete belonged to the failure mode 6 having a steeply decline curve after reaching the maximum load. Therefore, this results can make a contribution to the development of design standard.
키워드
- 제목
- 圓形 및 角形鋼管에 고강도 콘크리트를 充塡한 短柱의 軸壓縮擧動
- 제목 (타언어)
- Behavior of Circular and Square Stub Columns Filled With Variable High Strength Concrete under Concentrically Compressive Load
- 저자
- 강현식; 임서형; 문태섭
- 발행일
- 2004
- 저널명
- 대한건축학회논문집 구조계
- 권
- 20
- 호
- 4
- 페이지
- 25 ~ 34
- 출판사
- 대한건축학회
- 발행국가
- 대한민국
- 분량
- 10 페이지