상세 보기
공동주택 지하주차장 유공벽의 표면결로방지 기법 검토
- 정창헌;
- 김형근;
- 김태연;
- 서혜수
초록
The purpose of this study is to investigate the effective condensation reduction methods using double wall system in underground parking lot. Opening shape on the double wall, thermal properties of wall materials and indoor ventilation rates are the major variables. The result of the study indicates that opening shape with large linear opening at the top of the wall are the most effective opening shape for the surface temperature increase of the double wall. Reduced thermal conductance of the double wall material also contributed to the surface temperature increase slightly. The most effective method for the reduction of surface condensation risk is increasing indoor ventilation rate. Increased ventilation rate contributed to considerable surface temperature increases of all type of double walls with different opening shapes.
키워드
- 제목
- 공동주택 지하주차장 유공벽의 표면결로방지 기법 검토
- 제목 (타언어)
- Methods for Surface Condensation Prevention of Double Wall in Underground Parking Lots
- 저자
- 정창헌; 김형근; 김태연; 서혜수
- 발행일
- 2016
- 저널명
- 대한건축학회논문집
- 권
- 32
- 호
- 10
- 페이지
- 79 ~ 86
- 언어
- KOR
- 출판사
- 대한건축학회
- 발행국가
- 대한민국
- 분량
- 8 페이지
- ISSN
- E 2733-6247
P 2733-6239