LNG 배관 시스템용 1인치 글로브 밸브 개발 및 성능실험

Development and Performance Test on the 1-Inch Glove Valve for the LNG Piping System

초록

This study describes the development of a 1-inch cryogenic glove valve for an LNG pumping system and localization development achieved through the performance test. The cryogenic valve used in the LNG pumping system plays an important role in maintaining a flow rate by LNG transportation. This trial manufactured goods, which was achieved through reverse engineering and developing the assembly process. The result of the leak test satisfied the internal pressure condition using the 78-bar normal temperature test and maintained the anti-leakage condition. Also, the result of the cryogenic leak test (BS 6364: low temperature test procedure) maintained anti-leakage at -196 and 52 bar, which satisfied the test standards.

키워드

LNGCryogenicGlove Valve액화천연가스극저온글로브 밸브
제목
LNG 배관 시스템용 1인치 글로브 밸브 개발 및 성능실험
제목 (타언어)
Development and Performance Test on the 1-Inch Glove Valve for the LNG Piping System
저자
이중섭이치우
DOI
10.14775/ksmpe.2016.16.1.009
발행일
2017
저널명
한국기계가공학회지
16
1
페이지
9 ~ 16