건물의 냉각탑 제어 변경에 따른 연간 냉방 에너지 사용량 절감에 관한 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 하주완 | - |
| dc.contributor.author | 박경순 | - |
| dc.contributor.author | 김환용 | - |
| dc.contributor.author | 송영학 | - |
| dc.date.accessioned | 2022-12-26T15:32:09Z | - |
| dc.date.available | 2022-12-26T15:32:09Z | - |
| dc.date.issued | 2019 | - |
| dc.identifier.issn | 1976-6483 | - |
| dc.identifier.issn | 2586-0666 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/9965 | - |
| dc.description.abstract | The purpose of this study is to find out the efficiency improvement of the cooling system and cut-off of cooling energy consumption by changing the design method of the cooling tower system applied in Korea. The quantitative analysis was carried out on the cooling energy consumption saved by changing the Korea Standard design temperature of cooling tower system through EnergyPlus simulation. As a result of the simulation, when the condenser water temperature difference from the existing cooling tower design standard is 5K to 7K, the annual cooling energy consumption is reduced by 27,084 kWh, approximately 7.6%. Also, additionally, when the condenser water leaving temperature form the existing cooling tower design standard is 32°C to 23.9°C according to ASHRAE 90.1, the annual cooling energy consumption was reduced by 59.419 kWh, and approximately 16.7%. | - |
| dc.format.extent | 12 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국건축친환경설비학회 | - |
| dc.title | 건물의 냉각탑 제어 변경에 따른 연간 냉방 에너지 사용량 절감에 관한 연구 | - |
| dc.title.alternative | A Study on Annual Cooling Energy Consumption Cut-off with Cooling Tower Control Change | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.22696/jkiaebs.20190043 | - |
| dc.identifier.bibliographicCitation | 한국건축친환경설비학회 논문집, v.13, no.6, pp 503 - 514 | - |
| dc.citation.title | 한국건축친환경설비학회 논문집 | - |
| dc.citation.volume | 13 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 503 | - |
| dc.citation.endPage | 514 | - |
| dc.identifier.kciid | ART002544419 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Cooling system | - |
| dc.subject.keywordAuthor | Cooling tower control | - |
| dc.subject.keywordAuthor | Low temperature condenser water | - |
| dc.subject.keywordAuthor | Cooling energy cut-off | - |
| dc.subject.keywordAuthor | 냉방시스템 | - |
| dc.subject.keywordAuthor | 냉각탑제어 | - |
| dc.subject.keywordAuthor | 저온냉각수 | - |
| dc.subject.keywordAuthor | 냉방에너지절감 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.