| dc.description.abstract | This study evaluated natural lighting performance of Kwangajeong, the traditional housing in South Korea. Window-to-wall ratios were calculated by using the drawing documents. Daylighting factors were determined by field measurement. The results indicate that daylighting factor of the Kwangajeong is slightly low comparing present sustainable building design guide in South Korea even though the window-to-wall ratios are relatively high. It is thought that the relatively low daylighting factor are resulted by the low transmittance of Changhoji, the paper used on windows and Cheoma, eaves of the roof. | - |
| dc.format.extent | 9 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국건축친환경설비학회 | - |
| dc.title | 관가정의 창면적비와 주광률 검토를 통한 자연채광 성능 분석 | - |
| dc.title.alternative | Analysis of Natural Lighting Performance of Kwangajeong according to Window-to-Wall Ratios and Daylighting Factors | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.22696/jkiaebs.20190024 | - |
| dc.identifier.bibliographicCitation | 한국건축친환경설비학회 논문집, v.13, no.4, pp 281 - 289 | - |
| dc.citation.title | 한국건축친환경설비학회 논문집 | - |
| dc.citation.volume | 13 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 281 | - |
| dc.citation.endPage | 289 | - |
| dc.identifier.kciid | ART002495175 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | 관가정 | - |
| dc.subject.keywordAuthor | 주광률 | - |
| dc.subject.keywordAuthor | 자연채광 | - |
| dc.subject.keywordAuthor | 실측 | - |
| dc.subject.keywordAuthor | 창면적비 | - |
| dc.subject.keywordAuthor | Kwangajeong | - |
| dc.subject.keywordAuthor | Daylighting factor | - |
| dc.subject.keywordAuthor | Natural lighting | - |
| dc.subject.keywordAuthor | Field measurement | - |
| dc.subject.keywordAuthor | Window-to-wall ratio | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.