Detailed Information

Cited 49 time in webofscience Cited 56 time in scopus
Metadata Downloads

Clinical Feasibility of Zero TE Skull MRI in Patients with Head Trauma in Comparison with CT: A Single-Center Studyopen access

Authors
Cho, S. B.Baek, H. J.Ryu, K. H.Choi, B. H.Moon, J. I.Kim, T. B.Kim, S. K.Park, H.Hwang, M. J.
Issue Date
Jan-2019
Publisher
American Society of Neuoradiology
Citation
American Journal of Neuroradiology, v.40, no.1, pp 109 - 115
Pages
7
Indexed
SCI
SCIE
SCOPUS
Journal Title
American Journal of Neuroradiology
Volume
40
Number
1
Start Page
109
End Page
115
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/9572
DOI
10.3174/ajnr.A5916
ISSN
0195-6108
1936-959X
Abstract
BACKGROUND AND PURPOSE: Conventional MR imaging techniques cannot produce optimal images of bone structures because bone has little water and a very short T2 life span. The aim of this study was to investigate the clinical feasibility of skull MR imaging using the zero TE sequence in patients with head trauma by assessing its diagnostic image quality and quantitative measurement compared with CT images. MATERIALS AND METHODS: Thirteen enrolled patients with head trauma were assessed using brain CT and skull MR imaging. Image quality was graded on a 5-point Likert scale to compare the 2 modalities. To evaluate quantitative analyses between the 2 imaging modalities, we measured skull thickness and normalized bone tissue signal. Interobserver reliability was assessed using weighted kappa statistics and the intraclass correlation coefficient. RESULTS: Both imaging techniques clearly depicted skull fractures in all 13 patients. The mean scores for skull MR imaging and CT were 4.65 +/- 0.56 and 4.73 +/- 0.45 (P = .157), respectively, with substantial interobserver agreement (P < .05). The 2 imaging modalities showed no difference in skull thickness (P = .092) and had good correlation (r(2) = 0.997). The mean value of normalized bone tissue signal among the 3 layers of the skull was relatively consistent (P = .401) with high interobserver agreement (P < .001). CONCLUSIONS: Zero TE skull MR imaging has diagnostic image quality comparable with that of CT images. It also provides consistent results on the quantitative measurement of cortical bone with CT images.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE