Detailed Information

Cited 19 time in webofscience Cited 21 time in scopus
Metadata Downloads

Clinical feasibility of 1-min ultrafast brain MRI compared with routine brain MRI using synthetic MRI: a single center pilot study

Authors
Ryu, Kyeong HwaChoi, Dae SeobBaek, Hye JinCho, Soo BuemHa, Ji YoungKim, Tae ByeongHwang, Moon Jung
Issue Date
Feb-2019
Publisher
Dr. Dietrich Steinkopff Verlag
Keywords
Ultrafast MRI; Synthetic MRI; Fast imaging; Brain; Image quality
Citation
Journal of Neurology, v.266, no.2, pp 431 - 439
Pages
9
Indexed
SCI
SCIE
SCOPUS
Journal Title
Journal of Neurology
Volume
266
Number
2
Start Page
431
End Page
439
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/9463
DOI
10.1007/s00415-018-9149-4
ISSN
0340-5354
1432-1459
Abstract
BackgroundUltrafast brain MRI is required for uncooperative patients and time-critical diseases such as stroke because it reduces scan times and motion artifacts. This study investigated the clinical feasibility of a 1-min ultrafast brain MRI protocol for detecting intracranial abnormalities in restless and uncooperative patients.MethodsWe retrospectively reviewed the records of 25 patients who underwent a 1-min ultrafast MRI protocol using T1-weighted image, T2-weighted image, echo-planar fluid-attenuated inversion recovery, diffusion-weighted image, and T2*-weighted image between March 2017 and May 2017. Simple methods were applied for ultrafast MRI protocol to reduce scan time as follows: parallel imaging techniques, multiband technique on diffusion sequence, and echo-planar fluid-attenuated inversion recovery. The images were compared with the routine brain MRI protocol using synthetic MRI, and quality was assessed by two independent readers. The Wilcoxon signed-rank test was used to compare the readers' ratings of the routine MRI protocol and ultrafast MRI protocol images.ResultsUsing a four-point assessment scale, overall image quality and anatomical delineation of ultrafast brain MRI images were lower than those of routine brain MRI images. However, the ultrafast protocol demonstrated sufficient overall image quality and anatomical delineation with an assessment rating greater than two points. The ultrafast protocol had fewer artifacts than the routine protocol using synthetic MRI.ConclusionsAlthough the overall image quality and anatomical delineation of the 1-min ultrafast MRI were inferior to those of the routine brain MRI protocol, the ultrafast protocol showed at least sufficient image quality. Therefore, this protocol may be an option in specific clinical situations involving non-cooperative, restless, or pediatric patients, or patients with time-critical disease such as stroke. Further study is required to validate our findings.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Dae Seob photo

Choi, Dae Seob
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE