Cited 11 time in
Clinical feasibility and effectiveness of bedside peripherally inserted central catheter using portable digital radiography for patients in an intensive care unit A single-center experience
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Cho, Soo Buem | - |
| dc.contributor.author | Baek, Hye Jin | - |
| dc.contributor.author | Park, Sung Eun | - |
| dc.contributor.author | Choi, Ho Cheol | - |
| dc.contributor.author | Lee, Sang Min | - |
| dc.contributor.author | Bae, Kyungsoo | - |
| dc.contributor.author | Jeon, Kyung Nyeo | - |
| dc.contributor.author | Ryu, Kyeong Hwa | - |
| dc.contributor.author | Moon, Jin Il | - |
| dc.contributor.author | Choi, Bo Hwa | - |
| dc.contributor.author | Ha, Ji Young | - |
| dc.date.accessioned | 2022-12-26T14:48:10Z | - |
| dc.date.available | 2022-12-26T14:48:10Z | - |
| dc.date.issued | 2019-06 | - |
| dc.identifier.issn | 0025-7974 | - |
| dc.identifier.issn | 1536-5964 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/9070 | - |
| dc.description.abstract | The aim of this study was to evaluate the clinical feasibility and effectiveness of bedside peripherally inserted central catheter (PICC) using portable digital radiography (DR) in intensive care unit (ICU) patients. Sixty-five ICU patients who underwent PICC were enrolled in this study between May 2016 and May 2017. Of these 65 patients, 45 (69.2%) underwent the procedures bedside in ICU using portable DR, and 20 (30.8%) underwent the procedures at the intervention clinic, both performed by a single interventional radiologist. We retrospectively reviewed electronic medical records for clinical presentation, total procedural time, total radiation dose, total patient transfer time, and clinical outcomes. We performed an independent t test to compare the clinical effectiveness between the 2 groups. The technical and clinical success rates were 100% in both groups, and there were no procedure-related complications. The total radiation dose of bedside PICC at ICU was significantly lower than that of conventional PICC at the intervention clinic (557.9 mGy*cm(2) +/- 209.2 vs 985.2 mGy*cm(2) +/- 547.6, P<.001). The total procedure time was significantly different between the bedside and conventional PICC groups (26.8 minutes +/- 3.9 vs 24.1 minutes +/- 5.55, P=.028). The average patient transfer time to the intervention clinic was 26.6 minutes +/- 9.8. Bedside PICC using portable DR is a safe and effective procedure option to manage ICU patients in daily clinical practice. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Lippincott Williams & Wilkins Ltd. | - |
| dc.title | Clinical feasibility and effectiveness of bedside peripherally inserted central catheter using portable digital radiography for patients in an intensive care unit A single-center experience | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1097/MD.0000000000016197 | - |
| dc.identifier.scopusid | 2-s2.0-85069269863 | - |
| dc.identifier.wosid | 000480733400072 | - |
| dc.identifier.bibliographicCitation | Medicine, v.98, no.26, pp e16197 | - |
| dc.citation.title | Medicine | - |
| dc.citation.volume | 98 | - |
| dc.citation.number | 26 | - |
| dc.citation.startPage | e16197 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | General & Internal Medicine | - |
| dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
| dc.subject.keywordPlus | VENOUS CATHETERS | - |
| dc.subject.keywordPlus | TIP POSITION | - |
| dc.subject.keywordPlus | MALPOSITION | - |
| dc.subject.keywordPlus | SYSTEM | - |
| dc.subject.keywordPlus | PICC | - |
| dc.subject.keywordAuthor | bedside procedure | - |
| dc.subject.keywordAuthor | intensive care unit | - |
| dc.subject.keywordAuthor | peripherally inserted central catheter | - |
| dc.subject.keywordAuthor | portable digital radiography | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.