Cooling energy reduction effect of parallel double-window system operation in residential buildings in South Korea
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Seung-Won | - |
| dc.contributor.author | Leigh, Seung-Bok | - |
| dc.contributor.author | Kim, Taeyeon | - |
| dc.contributor.author | Cheong, Chang Heon | - |
| dc.contributor.author | Cho, Sooyoun | - |
| dc.date.accessioned | 2022-12-26T14:48:07Z | - |
| dc.date.available | 2022-12-26T14:48:07Z | - |
| dc.date.issued | 2019-06 | - |
| dc.identifier.issn | 1420-326X | - |
| dc.identifier.issn | 1423-0070 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/9065 | - |
| dc.description.abstract | This paper aims to derive the operational modes of a parallel double-window system that reduces cooling energy consumption and satisfies indoor comfort through natural ventilation. The parallel double-window system examined in this paper is a window system that could control indoor draft distribution and adjust the size of the opening depending on indoor and outdoor conditions. The system can be used in five ways (all close, out-open + in close, out-open+in open (tilt), out-open+in open (turn) and all open). This work verified the energy savings and indoor comfort of the existing mode experimentally, which were originally derived based on simple calculations at the time when the parallel double-window system was developed. A new operation mode, Alt 1, was derived, which addressed problems of the existing mode. In addition, in this work, the operation mode Alt 2 was derived, which simplified Alt 1 so that the actual occupant can use the system easily. By measuring these three operation modes and comparing the results with those of energy plus simulations, the work derived the amount of cooling energy savings and the level of indoor comfort through the use of an appropriate operation mode during inter-seasonal periods. Compared to when the natural ventilation operation mode was not used, cooling energy consumption was reduced by 60% when the operation mode was in use. The cooling temperature set point could have a significant impact on cooling energy consumption. | - |
| dc.format.extent | 23 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | SAGE PUBLICATIONS LTD | - |
| dc.title | Cooling energy reduction effect of parallel double-window system operation in residential buildings in South Korea | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1177/1420326X17707564 | - |
| dc.identifier.scopusid | 2-s2.0-85042540551 | - |
| dc.identifier.wosid | 000469879100006 | - |
| dc.identifier.bibliographicCitation | INDOOR AND BUILT ENVIRONMENT, v.28, no.5, pp 636 - 658 | - |
| dc.citation.title | INDOOR AND BUILT ENVIRONMENT | - |
| dc.citation.volume | 28 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 636 | - |
| dc.citation.endPage | 658 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Construction & Building Technology | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Public, Environmental & Occupational Health | - |
| dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Environmental | - |
| dc.relation.journalWebOfScienceCategory | Public, Environmental & Occupational Health | - |
| dc.subject.keywordPlus | NIGHT VENTILATION | - |
| dc.subject.keywordPlus | BEHAVIOR | - |
| dc.subject.keywordPlus | MODEL | - |
| dc.subject.keywordAuthor | Natural ventilation | - |
| dc.subject.keywordAuthor | Double-window system | - |
| dc.subject.keywordAuthor | Indoor thermal environment | - |
| dc.subject.keywordAuthor | Cooling energy | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.