Detailed Information

Cited 10 time in webofscience Cited 11 time in scopus
Metadata Downloads

Cooling energy reduction effect of parallel double-window system operation in residential buildings in South Korea

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Seung-Won-
dc.contributor.authorLeigh, Seung-Bok-
dc.contributor.authorKim, Taeyeon-
dc.contributor.authorCheong, Chang Heon-
dc.contributor.authorCho, Sooyoun-
dc.date.accessioned2022-12-26T14:48:07Z-
dc.date.available2022-12-26T14:48:07Z-
dc.date.issued2019-06-
dc.identifier.issn1420-326X-
dc.identifier.issn1423-0070-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/9065-
dc.description.abstractThis paper aims to derive the operational modes of a parallel double-window system that reduces cooling energy consumption and satisfies indoor comfort through natural ventilation. The parallel double-window system examined in this paper is a window system that could control indoor draft distribution and adjust the size of the opening depending on indoor and outdoor conditions. The system can be used in five ways (all close, out-open + in close, out-open+in open (tilt), out-open+in open (turn) and all open). This work verified the energy savings and indoor comfort of the existing mode experimentally, which were originally derived based on simple calculations at the time when the parallel double-window system was developed. A new operation mode, Alt 1, was derived, which addressed problems of the existing mode. In addition, in this work, the operation mode Alt 2 was derived, which simplified Alt 1 so that the actual occupant can use the system easily. By measuring these three operation modes and comparing the results with those of energy plus simulations, the work derived the amount of cooling energy savings and the level of indoor comfort through the use of an appropriate operation mode during inter-seasonal periods. Compared to when the natural ventilation operation mode was not used, cooling energy consumption was reduced by 60% when the operation mode was in use. The cooling temperature set point could have a significant impact on cooling energy consumption.-
dc.format.extent23-
dc.language영어-
dc.language.isoENG-
dc.publisherSAGE PUBLICATIONS LTD-
dc.titleCooling energy reduction effect of parallel double-window system operation in residential buildings in South Korea-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1177/1420326X17707564-
dc.identifier.scopusid2-s2.0-85042540551-
dc.identifier.wosid000469879100006-
dc.identifier.bibliographicCitationINDOOR AND BUILT ENVIRONMENT, v.28, no.5, pp 636 - 658-
dc.citation.titleINDOOR AND BUILT ENVIRONMENT-
dc.citation.volume28-
dc.citation.number5-
dc.citation.startPage636-
dc.citation.endPage658-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaConstruction & Building Technology-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaPublic, Environmental & Occupational Health-
dc.relation.journalWebOfScienceCategoryConstruction & Building Technology-
dc.relation.journalWebOfScienceCategoryEngineering, Environmental-
dc.relation.journalWebOfScienceCategoryPublic, Environmental & Occupational Health-
dc.subject.keywordPlusNIGHT VENTILATION-
dc.subject.keywordPlusBEHAVIOR-
dc.subject.keywordPlusMODEL-
dc.subject.keywordAuthorNatural ventilation-
dc.subject.keywordAuthorDouble-window system-
dc.subject.keywordAuthorIndoor thermal environment-
dc.subject.keywordAuthorCooling energy-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > School of Architectural Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cheong, Chang Heon photo

Cheong, Chang Heon
공과대학 (건축공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE