Cited 0 time in
T1 mapping for liver function evaluation in gadoxetic acid-enhanced MR imaging: comparison of look-locker inversion recovery and B-1 inhomogeneity-corrected variable flip angle method
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Ji Eun | - |
| dc.contributor.author | Kim, Hyun Ok | - |
| dc.contributor.author | Bae, Kyungsoo | - |
| dc.contributor.author | Choi, Dae Seob | - |
| dc.contributor.author | Nickel, Dominik | - |
| dc.date.accessioned | 2022-12-26T14:47:12Z | - |
| dc.date.available | 2022-12-26T14:47:12Z | - |
| dc.date.issued | 2019-07 | - |
| dc.identifier.issn | 0938-7994 | - |
| dc.identifier.issn | 1432-1084 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/8988 | - |
| dc.description.abstract | ObjectivesTo compare look-locker inversion recovery (LLIR) and B-1 inhomogeneity-corrected variable flip angle T1 mapping methods for estimation of liver function and prediction of hepatic insufficiency and decompensation on gadoxetic acid-enhanced MR imaging.MethodsIn this retrospective study, 248 patients with normal liver function, chronic liver disease, or cirrhosis underwent gadoxetic acid-enhanced liver MR imaging, including T1 mapping at 10-min and 20-min hepatobiliary phase (HBP) by using both methods. T1 relaxation times of the liver (T1(Liver-pre), T1(Liver-post)) and the spleen (T1(Spleen)) were correlated between two methods. T1(Liver) ([T1(Liver-pre) - T1(Liver-post)]/T1(Liver-pre)), adjusted T1(Liver) ([T1(Spleen) - T1(Liver-post)]/T1(Spleen)), and functional liver volume-to-weight ratio (liver volume on volumetric T1 map/[T1(Liver-post) x patient's weight]) were calculated. The diagnostic performance of T1 parameters and the predictive performance of models (serum marker, serum marker plus T1 parameter) were compared.ResultsT1(Liver-post) showed a strong correlation (r=0.93, p<0.001) between two methods but was significantly different. For depicting cirrhosis, LLIR-adjusted T1(Liver) at 10-min HBP showed the highest performance (p<0.025). For predicting hepatic insufficiency and decompensation, LLIR-adjusted T1(Liver) (Akaike information criterion (AIC), 58.37; C-index, 0.867) and LLIR-T1(Liver-post) (AIC, 48.82; C-index, 0.885) at 10-min HBP showed the best performance, respectively, when added to serum albumin level.ConclusionsT1(Liver-post) showed a strong correlation between two methods but with significant differences. T1 mapping using LLIR at 10-min HBP with obtainment of adjusted T1(Liver) and T1(Liver-post) may be the best approach for estimation of liver function and prediction of hepatic insufficiency and decompensation.Key Points center dot T1(Liver-post)showed a strong correlation between LLIR and B(1)inhomogeneity-corrected VFA methods, both at 10-min and 20-min HBP but with significant differences.center dot T1(Liver-post)at 10-min and 20-min HBP using LLIR and B(1)inhomogeneity-corrected VFA methods could not be used interchangeably during the follow-up in patients with chronic liver disease (CLD) or cirrhosis.center dot T1 mapping using LLIR at 10-min HBP with obtainment of adjusted T1(Liver)and T1(Liver-post)may be the most suitable method and parameter for estimation of global liver function and prediction of clinical outcomes in patients with CLD or cirrhosis. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Springer Verlag | - |
| dc.title | T1 mapping for liver function evaluation in gadoxetic acid-enhanced MR imaging: comparison of look-locker inversion recovery and B-1 inhomogeneity-corrected variable flip angle method | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1007/s00330-018-5947-4 | - |
| dc.identifier.scopusid | 2-s2.0-85069945170 | - |
| dc.identifier.wosid | 000470679400028 | - |
| dc.identifier.bibliographicCitation | European Radiology, v.29, no.7, pp 3584 - 3594 | - |
| dc.citation.title | European Radiology | - |
| dc.citation.volume | 29 | - |
| dc.citation.number | 7 | - |
| dc.citation.startPage | 3584 | - |
| dc.citation.endPage | 3594 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | RELAXATION-TIME INDEX | - |
| dc.subject.keywordPlus | QUANTITATIVE-EVALUATION | - |
| dc.subject.keywordPlus | HEPATITIS-C | - |
| dc.subject.keywordPlus | FIBROSIS | - |
| dc.subject.keywordPlus | T-1 | - |
| dc.subject.keywordPlus | QUANTIFICATION | - |
| dc.subject.keywordPlus | ELASTOGRAPHY | - |
| dc.subject.keywordPlus | TRANSPORTER | - |
| dc.subject.keywordPlus | EXPRESSION | - |
| dc.subject.keywordPlus | PARAMETERS | - |
| dc.subject.keywordAuthor | Liver | - |
| dc.subject.keywordAuthor | Magnetic resonance imaging | - |
| dc.subject.keywordAuthor | Gadoxetic acid | - |
| dc.subject.keywordAuthor | Cirrhosis | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.