Cited 21 time in
Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, D. | - |
| dc.contributor.author | Heo, Y. J. | - |
| dc.contributor.author | Jeong, H. W. | - |
| dc.contributor.author | Baek, J. W. | - |
| dc.contributor.author | Han, J-Y | - |
| dc.contributor.author | Lee, J. Y. | - |
| dc.contributor.author | Jin, S-C | - |
| dc.contributor.author | Baek, H. J. | - |
| dc.date.accessioned | 2022-12-26T14:33:52Z | - |
| dc.date.available | 2022-12-26T14:33:52Z | - |
| dc.date.issued | 2019-09 | - |
| dc.identifier.issn | 0195-6108 | - |
| dc.identifier.issn | 1936-959X | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/8793 | - |
| dc.description.abstract | BACKGROUND AND PURPOSE: Contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolution (SPACE) with the delay alternating with nutation for tailored excitation (DANTE) pulse could suppress the blood flow signal and provide a higher contrast-to-noise ratio of enhancing lesion-to-brain parenchyma than the MPRAGE sequence. The purpose of our study was to evaluate the usefulness of SPACE with DANTE compared with MPRAGE for detecting brain metastases. MATERIALS AND METHODS: Seventy-one patients who underwent contrast-enhanced SPACE with DANTE and MPRAGE sequences and who were suspected of having metastatic lesions were included. Two neuroradiologists determined the number of enhancing lesions, and diagnostic performance was evaluated using figure of merit, sensitivity, positive predictive value, interobserver agreement, and reading time. Contrast-to-noise ratio(lesion/parenchyma) and contrast-to-noise ratio(white matter/gray matter) were also assessed. RESULTS: SPACE with DANTE (observer one, 328; observer two, 324) revealed significantly more small (<5 mm) enhancing lesions than MPRAGE (observer one, 175; observer two, 150) (P < 0.001 for observer 1, P <= .0001 for observer 2). Furthermore, SPACE with DANTE showed significantly higher figure of merit and sensitivity and shorter reading time than MPRAGE for both observers. The mean contrast-to-noise ratio(lesion/parenchyma) of SPACE with DANTE (52.3 +/- 43.1) was significantly higher than that of MPRAGE (17.5 +/- 19.3) (P <= .0001), but the mean contrast-to-noise ratio(white matter/gray matter) of SPACE with DANTE (-0.65 +/- 1.39) was significantly lower than that of MPRAGE (3.08 +/- 1.39) (P <= .0001). CONCLUSIONS: Compared with MPRAGE, SPACE with DANTE significantly improves the detection of brain metastases. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | American Society of Neuoradiology | - |
| dc.title | Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.3174/ajnr.A6158 | - |
| dc.identifier.scopusid | 2-s2.0-85071787441 | - |
| dc.identifier.wosid | 000484519300009 | - |
| dc.identifier.bibliographicCitation | American Journal of Neuroradiology, v.40, no.9, pp 1469 - 1475 | - |
| dc.citation.title | American Journal of Neuroradiology | - |
| dc.citation.volume | 40 | - |
| dc.citation.number | 9 | - |
| dc.citation.startPage | 1469 | - |
| dc.citation.endPage | 1475 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Neurosciences & Neurology | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Clinical Neurology | - |
| dc.relation.journalWebOfScienceCategory | Neuroimaging | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | SPIN-ECHO | - |
| dc.subject.keywordPlus | BRAIN METASTASES | - |
| dc.subject.keywordPlus | LESION ENHANCEMENT | - |
| dc.subject.keywordPlus | BLACK-BLOOD | - |
| dc.subject.keywordPlus | OBSERVER | - |
| dc.subject.keywordPlus | MANAGEMENT | - |
| dc.subject.keywordPlus | 2D | - |
| dc.subject.keywordPlus | 3T | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.