Enhanced fabrication of dual-compartment artificial cornea C-Clear via precision moulding and continuous polymerisation: biocompatibility and functional efficacy in rabbit model

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Tae-Hyun-
dc.contributor.authorPark, Jae Hong-
dc.contributor.authorChoi, Eun Ji-
dc.contributor.authorJeong, Do-Sun-
dc.contributor.authorKim, Joong-Hyun-
dc.contributor.authorKim, Chul Min-
dc.date.accessioned2026-01-22T06:00:07Z-
dc.date.available2026-01-22T06:00:07Z-
dc.date.issued2025-12-
dc.identifier.issn2050-750X-
dc.identifier.issn2050-7518-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/82059-
dc.description.abstractThis study introduces C-Clear, a novel artificial cornea based on a HEMA/MMA-based copolymer, developed through continuous polymerisation and moulding. C-Clear comprises a transparent optical core and porous support skirt, specifically designed to enhance tissue integration and minimise inflammatory responses. In vitro evaluations demonstrated excellent biocompatibility, characterised by high levels of cell adhesion and proliferation, while in vivo assessments using a rat subcutaneous model confirmed successful integration and biocompatibility. Furthermore, a 24-week corneal implantation study in rabbits validated the stability, safety, and functional potential of C-Clear. Serial ophthalmic examinations during this study period showed no significant progression of neovascularisation or inflammation. Histological analyses revealed exceptional optical clarity, robust integration with surrounding tissues, and an absence of notable foreign body responses. The implant achieved a retention rate of 75% over the 24 weeks, further highlighting its reliability. The custom-designed mould and continuous polymerisation process enabled the fabrication of C-Clear with superior structural stability, biocompatibility, and therapeutic efficacy. These findings highlight C-Clear as a significant advancement in artificial corneal development, addressing the global shortage of donor corneas and offering a promising solution for treating corneal blindness.-
dc.language영어-
dc.language.isoENG-
dc.publisherRoyal Society of Chemistry-
dc.titleEnhanced fabrication of dual-compartment artificial cornea C-Clear via precision moulding and continuous polymerisation: biocompatibility and functional efficacy in rabbit model-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1039/d5tb01842k-
dc.identifier.scopusid2-s2.0-105026556241-
dc.identifier.wosid001653741200001-
dc.identifier.bibliographicCitationJournal of Materials Chemistry B-
dc.citation.titleJournal of Materials Chemistry B-
dc.type.docTypeArticle; Early Access-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalWebOfScienceCategoryMaterials Science, Biomaterials-
dc.subject.keywordPlusCELL-ADHESION-
dc.subject.keywordPlusBIOMATERIALS-
dc.subject.keywordPlusBLINDNESS-
dc.subject.keywordPlusTRANSPLANTATION-
dc.subject.keywordPlusMACROPHAGES-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chul Min photo

Kim, Chul Min
IT공과대학 (메카트로닉스공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE