Detailed Information

Cited 0 time in webofscience Cited 41 time in scopus
Metadata Downloads

Initial clinical experience of synthetic MRI as a routine neuroimaging protocol in daily practice: A single-center study

Full metadata record
DC Field Value Language
dc.contributor.authorRyu, K.H.-
dc.contributor.authorBaek, H.J.-
dc.contributor.authorMoon, J.I.-
dc.contributor.authorChoi, B.H.-
dc.contributor.authorPark, S.E.-
dc.contributor.authorHa, J.Y.-
dc.contributor.authorJeon, K.N.-
dc.contributor.authorBae, K.-
dc.contributor.authorChoi, D.S.-
dc.contributor.authorCho, S.B.-
dc.contributor.authorLee, Y.-
dc.contributor.authorHeo, Y.J.-
dc.date.accessioned2022-12-26T14:02:37Z-
dc.date.available2022-12-26T14:02:37Z-
dc.date.issued2020-03-
dc.identifier.issn0150-9861-
dc.identifier.issn1773-0406-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/8198-
dc.description.abstractBackground and purpose: We investigated the clinical feasibility of synthetic MRI with a 4-min single scan using a 48-channel head coil as a routine neuroimaging protocol in daily practice by assessing its diagnostic image quality. Methods: We retrospectively reviewed the imaging data of 89 patients who underwent routine brain MRI using synthetic MRI acquisition between February 2017 and April 2017. Image quality assessments were performed by two independent readers on synthetic T1 fluid-attenuated inversion recovery (FLAIR), T2-weighted, T2 FLAIR, and phase-sensitive inversion recovery sequences acquired using multiple-dynamic multiple-echo imaging. Interobserver reliability between the two readers was assessed using kappa (κ) statistics. Results: On a 4-point assessment scale, the overall image quality and anatomical delineation provided by synthetic brain MRI were found to be good with scores of more than 3 points for all sequences except for the T2 FLAIR sequence. The synthetic T2 FLAIR sequence provided sufficient image quality but showed more pronounced artifacts, especially the CSF pulsation artifact and linear hyperintensity along the brain surface. Interobserver agreement for evaluating image quality of all synthetic sequences was good to excellent (κ, 0.61?0.99; P < 0.001). Conclusion: Synthetic MRI can be acceptable as a routine clinical neuroimaging protocol with a short scan time. It can be helpful to design customized and flexible neuroimaging protocols for each institution. ? 2019 Elsevier Masson SAS-
dc.format.extent10-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier Masson-
dc.titleInitial clinical experience of synthetic MRI as a routine neuroimaging protocol in daily practice: A single-center study-
dc.typeArticle-
dc.publisher.location프랑스-
dc.identifier.doi10.1016/j.neurad.2019.03.002-
dc.identifier.scopusid2-s2.0-85064210116-
dc.identifier.bibliographicCitationJournal of Neuroradiology, v.47, no.2, pp 151 - 160-
dc.citation.titleJournal of Neuroradiology-
dc.citation.volume47-
dc.citation.number2-
dc.citation.startPage151-
dc.citation.endPage160-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordAuthorBrain MRI-
dc.subject.keywordAuthorDiagnostic image quality-
dc.subject.keywordAuthorMAGiC-
dc.subject.keywordAuthorRoutine neuroimaging protocol-
dc.subject.keywordAuthorSynthetic MRI-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles
의학계열 > 의학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeon, Kyung Nyeo photo

Jeon, Kyung Nyeo
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE