Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

딥러닝 기반 질량분석 스펙트럼 분석을 이용한 생물 탐지 정확도 향상 연구Enhancing Accuracy of Bio-detection by Analyzing Mass Spectrometry Spectra Using Deep Learning

Other Titles
Enhancing Accuracy of Bio-detection by Analyzing Mass Spectrometry Spectra Using Deep Learning
Authors
정재윤문상준추원식
Issue Date
Dec-2025
Publisher
국방기술품질원
Keywords
deep learning; biological agents; mass spectrometry; Chemical and Biological Mass Spectrometer(CBMS); Residual Neural Network(ResNet)
Citation
국방품질연구논집(JDQS), v.7, no.2, pp 64 - 74
Pages
11
Indexed
KCI
Journal Title
국방품질연구논집(JDQS)
Volume
7
Number
2
Start Page
64
End Page
74
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/81808
DOI
10.23199/jdqs.2025.7.2.006
ISSN
2671-4744
Abstract
This paper presents a highly reliable biological detection method to improve the field performance of chemical and biological mass spectrometry. Existing algorithms, which rely on a few pre-selected biomarkers, are susceptible to false alarms owing to external interference in real-world environments. Our approach leverages a deep-learning-based classification algorithm, specifically the ResNet-50 architecture, which is trained to recognize the entire spectral pattern from ion mass spectrometry data. Datasets were secured from both laboratory and field environments, including samples of bacteria, spores, biological toxins, and a “no agent injected” control. Data augmentation techniques were developed to simulate device malfunctions and enhance the robustness of the algorithm. The trained model was deployed on a military-grade single-board computer , which achieved real-time analysis within 5 s. Field testing on new and unseen data resulted in a classification accuracy of 99.348%, thus demonstrating a significant improvement over conventional biomarker-based methods. Additionally, the LIME technique was utilized to provide interpretability, which showed that the model focused on specific biomarker regions for classification. This study provides a robust and high-performance solution for detecting biological agents under challenging field conditions.
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > ETC > Journal Articles
학과간협동과정 > 기계융합공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chu, Won Shik photo

Chu, Won Shik
공과대학 (기계융합공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE