High-resolution infrared Fourier ptychographic microscopy using InGaAs camera
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Oh, Gi-Seok | - |
| dc.contributor.author | Choi, Hyun | - |
| dc.date.accessioned | 2025-11-24T07:30:19Z | - |
| dc.date.available | 2025-11-24T07:30:19Z | - |
| dc.date.issued | 2026-01 | - |
| dc.identifier.issn | 0143-8166 | - |
| dc.identifier.issn | 1873-0302 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/80967 | - |
| dc.description.abstract | Imaging using infrared (IR) light sources has relatively long wavelengths compared to visible light, making it difficult to form small spot sizes. Furthermore, InGaAs cameras, widely used for infrared imaging with wavelengths exceeding 1000 nm, have larger pixels than silicon-based cameras used for visible light, making them unsuitable for high-resolution imaging. We propose a high-resolution IR Fourier ptychographic microscopy (FPM) technology consisting of an IR LED illuminator and a low-resolution InGaAs camera for high-resolution IR imaging. Using an objective lens with a numerical aperture (NA) of 0.4, we achieve a synthetic NA of 1.05 in the IR-FPM, which we experimentally verified through captured images from the USAF resolution chart. Furthermore, we demonstrate high-resolution imaging of internal cracks in Si wafers, leveraging the advantage of IR imaging that can penetrate Si substrates. The proposed method is expected to be widely utilized as a measurement technology in various industrial fields that use Si wafers substrates. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | High-resolution infrared Fourier ptychographic microscopy using InGaAs camera | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1016/j.optlaseng.2025.109434 | - |
| dc.identifier.scopusid | 2-s2.0-105020376547 | - |
| dc.identifier.wosid | 001611343300002 | - |
| dc.identifier.bibliographicCitation | Optics and Lasers in Engineering, v.196 | - |
| dc.citation.title | Optics and Lasers in Engineering | - |
| dc.citation.volume | 196 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Optics | - |
| dc.relation.journalWebOfScienceCategory | Optics | - |
| dc.subject.keywordPlus | WIDE-FIELD | - |
| dc.subject.keywordPlus | OPTIMIZATION | - |
| dc.subject.keywordPlus | DEPTH | - |
| dc.subject.keywordAuthor | Fourier ptychographic microscopy | - |
| dc.subject.keywordAuthor | Infrared imaging | - |
| dc.subject.keywordAuthor | High resolution imaging | - |
| dc.subject.keywordAuthor | InGaAs camera | - |
| dc.subject.keywordAuthor | Si wafer inspection | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.