Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

High-resolution infrared Fourier ptychographic microscopy using InGaAs camera

Full metadata record
DC Field Value Language
dc.contributor.authorOh, Gi-Seok-
dc.contributor.authorChoi, Hyun-
dc.date.accessioned2025-11-24T07:30:19Z-
dc.date.available2025-11-24T07:30:19Z-
dc.date.issued2026-01-
dc.identifier.issn0143-8166-
dc.identifier.issn1873-0302-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/80967-
dc.description.abstractImaging using infrared (IR) light sources has relatively long wavelengths compared to visible light, making it difficult to form small spot sizes. Furthermore, InGaAs cameras, widely used for infrared imaging with wavelengths exceeding 1000 nm, have larger pixels than silicon-based cameras used for visible light, making them unsuitable for high-resolution imaging. We propose a high-resolution IR Fourier ptychographic microscopy (FPM) technology consisting of an IR LED illuminator and a low-resolution InGaAs camera for high-resolution IR imaging. Using an objective lens with a numerical aperture (NA) of 0.4, we achieve a synthetic NA of 1.05 in the IR-FPM, which we experimentally verified through captured images from the USAF resolution chart. Furthermore, we demonstrate high-resolution imaging of internal cracks in Si wafers, leveraging the advantage of IR imaging that can penetrate Si substrates. The proposed method is expected to be widely utilized as a measurement technology in various industrial fields that use Si wafers substrates.-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier BV-
dc.titleHigh-resolution infrared Fourier ptychographic microscopy using InGaAs camera-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1016/j.optlaseng.2025.109434-
dc.identifier.scopusid2-s2.0-105020376547-
dc.identifier.wosid001611343300002-
dc.identifier.bibliographicCitationOptics and Lasers in Engineering, v.196-
dc.citation.titleOptics and Lasers in Engineering-
dc.citation.volume196-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOptics-
dc.relation.journalWebOfScienceCategoryOptics-
dc.subject.keywordPlusWIDE-FIELD-
dc.subject.keywordPlusOPTIMIZATION-
dc.subject.keywordPlusDEPTH-
dc.subject.keywordAuthorFourier ptychographic microscopy-
dc.subject.keywordAuthorInfrared imaging-
dc.subject.keywordAuthorHigh resolution imaging-
dc.subject.keywordAuthorInGaAs camera-
dc.subject.keywordAuthorSi wafer inspection-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > ETC > Journal Articles
학과간협동과정 > 기계융합공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Hyun photo

Choi, Hyun
공과대학 (기계융합공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE