Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development of Magnetization-based Eddy Current Sensors for In-Line Inspection of X65 Pipelinesopen access

Authors
Chae, Seung-AhnHa, Hyun-HoUm, Dae-YongPark, Gwan-Soo
Issue Date
Oct-2025
Publisher
Institute of Electrical and Electronics Engineers Inc.
Keywords
Eddy current testing (ECT); ferromagnetic pipeline; in-line inspection (ILI); magnetic flux leakage (MFL); non-destructive testing (NDT)
Citation
IEEE Access, v.13, pp 181617 - 181631
Pages
15
Indexed
SCIE
SCOPUS
Journal Title
IEEE Access
Volume
13
Start Page
181617
End Page
181631
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/80784
DOI
10.1109/ACCESS.2025.3623139
ISSN
2169-3536
2169-3536
Abstract
Traditional in-line inspection (ILI) methods, such as magnetic flux leakage testing (MFLT) and eddy current testing (ECT), have inherent limitations. MFLT suffers from high magnetic attraction forces, which result in excessive friction and instability in low-pressure, low-flow (LP-LF) pipelines. Conversely, conventional ECT is limited in its ability to detect buried defects due to shallow penetration depth. To address these issues, magnetization-based eddy current testing (MB-ECT) has emerged as a promising alternative. It requires lower magnetization than MFLT while effectively detecting both surface and buried defects. Effective implementation of MB-ECT requires optimization of design parameters tailored to the characteristics of the targeted defects and inspection conditions. In this study, an MB-ECT system was developed and optimized. The correlation between defect signals and key parameters—probe configuration, driving frequency, and magnetization level—was investigated through finite element analysis (FEA) and lab-scale experiments. Based on parametric analysis, two MB-ECT probe models were developed: a detection-priority model and a low-force-priority model. Both models demonstrated sufficient detectability under lab-scale noise conditions, with the minimum defect signals achieving SNRs of 11.4 dB and 9.25 dB, respectively. Although the low-force-priority model showed a 15.8% reduction in sensitivity to outer defects compared to the detection-priority model, it offered notable design benefits: an 18.8% reduction in magnetic attraction forces and a 23.7% decrease in magnetizer volume. The low-force model minimizes performance degradation and supports effective use under LP-LF pipeline conditions. These findings offer practical design guidelines for implementing MB-ECT–based ILI tools tailored to pipeline operating environments.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Um, Dae Yong photo

Um, Dae Yong
IT공과대학 (전기공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE