Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Initial Assessment of Dual-Energy CT in Patients With Gallstones or Bile Duct Stones: Can Virtual Nonenhanced Images Replace True Nonenhanced Images?

Authors
Kim, Ji EunLee, Jeong MinBaek, Jee HyunHan, Joon KooChoi, Byung Ihn
Issue Date
Apr-2012
Publisher
American Roentgen Ray Society
Keywords
bile duct stones; dual-energy CT; gallstones; virtual nonenhanced images
Citation
American Journal of Roentgenology, v.198, no.4, pp 817 - 824
Pages
8
Indexed
SCI
SCIE
SCOPUS
Journal Title
American Journal of Roentgenology
Volume
198
Number
4
Start Page
817
End Page
824
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/80307
DOI
10.2214/AJR.11.6972
ISSN
0361-803X
1546-3141
Abstract
OBJECTIVE. The purpose of our study was to investigate whether virtual nonenhanced images can replace true nonenhanced images for the evaluation of biliary stones and to compare two virtual nonenhanced images obtained from dual-energy data sets during the late arterial phase (LAP) and portal venous phase (PVP) with true nonenhanced images. MATERIALS AND METHODS. One hundred patients with gallstones (n = 77) or bile duct stones (n = 23) who had undergone dual-source dual-energy CT (using 80kVp and 140kVp with the ratio of dose-partitioning, 1: 1.3), were included. The CT numbers for the stone, liver, and bile; stone size; and image noise were assessed for each image set. The conspicuity and size of the stones, image quality, and acceptability of the virtual nonenhanced images as a replacement for true nonenhanced images were assessed. RESULTS. Virtual nonenhanced images from both LAP (VNELAP) and PVP showed lower CT numbers for the stone and smaller stone size than did true nonenhanced images (p < 0.05). VNELAP images failed to show stones in 16 patients (16%) with relatively radiolucent bile duct stones (< 78 HU) or small gallstones (< 9 mm(2), < 1.7 mm). There was no difference between the two virtual nonenhanced image sets except for the contrast-to-noise ratio of stone to bile and the image noise (CT numbers for the stone, liver, and muscle; stone size; and contrast-to-noise ratio of stone to liver, p = 1; the CT number for the bile, p = 0.1618; and effective dose, p = 0.7478). VNELAP images were considered acceptable as a replacement for true nonenhanced images in 89% and 90% by reviewers 1 and 2, respectively. CONCLUSION. Virtual nonenhanced images allow the detection of biliary stones with moderate accuracy, irrespective of the dual-energy contrast-enhanced phase. The detection of gallbladder stones of 9 mm(2) or smaller and of relatively radiolucent bile duct stones of 78 HU or lower is limited.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Eun photo

Kim, Ji Eun
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE