Cited 0 time in
Measurement of Convective Heat Transfer Coefficients of Horizontal Thermal Screens under Natural Conditions
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Adeel Rafiq | - |
| dc.contributor.author | Wook Ho Na | - |
| dc.contributor.author | Adnan Rasheed | - |
| dc.contributor.author | 김현태 | - |
| dc.contributor.author | 이현우 | - |
| dc.date.accessioned | 2022-12-26T14:01:08Z | - |
| dc.date.available | 2022-12-26T14:01:08Z | - |
| dc.date.issued | 2020 | - |
| dc.identifier.issn | 1229-4675 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/8028 | - |
| dc.description.abstract | Convective heat transfer is the main component of greenhouse energy loss because the energy loss by this mechanism is greater than those of the other two components (radiative and conductive). Previous studies have examined the convective heat transfer coefficients under natural conditions, but they are not applicable to symmetric thermal screens with zero porosity, and such screens are largely produced and used in Korea. However, the properties of these materials have not been reported in the literature, which causes selectivity issues for users. Therefore, in this study, three screens having similar color and zero porosity were selected, and a mathematical procedure based on radiation balance equations was developed to determine their convective heat transfer coefficients. To conduct the experiment, a hollow wooden structure was built and the thermal screen was tacked over this frame; the theoretical model was applied underneath and over the screen. Input parameters included three components: 1) solar and thermal fluxes; 2) temperature of the screen, black cloth, and ambient air; and 3) wind velocity. The convective heat transfer coefficients were determined as functions of the air–screen temperature difference under open-air environmental conditions. It was observed from the outcomes that the heat transfer coefficients decreased with the increase of the air–screen temperature difference provided that the wind velocity was nearly zero. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | (사) 한국생물환경조절학회 | - |
| dc.title | Measurement of Convective Heat Transfer Coefficients of Horizontal Thermal Screens under Natural Conditions | - |
| dc.title.alternative | Measurement of Convective Heat Transfer Coefficients of Horizontal Thermal Screens under Natural Conditions | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.12791/KSBEC.2020.29.1.9 | - |
| dc.identifier.bibliographicCitation | 생물환경조절학회지, v.29, no.1, pp 9 - 19 | - |
| dc.citation.title | 생물환경조절학회지 | - |
| dc.citation.volume | 29 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 9 | - |
| dc.citation.endPage | 19 | - |
| dc.identifier.kciid | ART002555390 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | 대류열전달계수 | - |
| dc.subject.keywordAuthor | 스크린 | - |
| dc.subject.keywordAuthor | 야간복사계 | - |
| dc.subject.keywordAuthor | 흡수율 | - |
| dc.subject.keywordAuthor | absorption | - |
| dc.subject.keywordAuthor | convective heat transfer coefficient | - |
| dc.subject.keywordAuthor | pyranometer | - |
| dc.subject.keywordAuthor | thermal screens | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
