Comparative Morphometric and Histometric Evaluation of Power-Dependent Tissue Ablation Using Fractional Carbon Dioxide Laseropen access
- Authors
- Ryu, Hye Guk; Park, Jinyoung; Kim, Hyemin; Kim, Wanil; Lee, Hwa-Rim; Ko, Jeongah; Cho, Sung Bin
- Issue Date
- Aug-2025
- Publisher
- Dove Medical Press Limited
- Keywords
- carbon dioxide; fractional laser; ablation; ex vivo pig skin; histometric evaluation; morphometric evaluation
- Citation
- Clinical, Cosmetic and Investigational Dermatology, v.18, pp 1901 - 1907
- Pages
- 7
- Indexed
- SCIE
SCOPUS
- Journal Title
- Clinical, Cosmetic and Investigational Dermatology
- Volume
- 18
- Start Page
- 1901
- End Page
- 1907
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/80012
- DOI
- 10.2147/CCID.S534637
- ISSN
- 1178-7015
- Abstract
- Background: Fractional carbon dioxide (CO2) lasers are commonly used in dermatological resurfacing, offering precise ablation and controlled dermal remodeling. Although clinical outcomes vary with the energy and pulse settings, comparative morphometric and histometric data on power-dependent tissue interactions are limited. Objective: To evaluate and compare fractional CO2 laser-induced microscopic thermal zones (MTZs) ablation characteristics at peak powers of 30 W and 40 W using an ex vivo porcine skin model. Methods: Ex vivo porcine skin was treated with a fractional CO2 laser at energy levels ranging from 40 to 240 mJ under 30 Wand 40 W settings. Frozen tissue was used for dermoscopic assessment of ablation diameters, while unfrozen tissue at physiological temperature (30-32 degrees C) was analyzed histologically for ablation depth. Morphometric and histometric measurements were performed and statistically analyzed. Results: The 30 W and 40 W settings demonstrated energy-dependent increases in ablation depth and diameter. The 40 W laser consistently generated deeper ablation columns (average 11.8% deeper) with narrower surface diameters (average 7.3% narrower) and reduced peripheral carbonization. Linear regression showed strong correlations between energy and ablation depth (r > 0.91) and diameter (r > 0.91), with higher slope coefficients in the 40 W group, indicating greater ablation efficiency. Conclusion: The 40 W fractional CO2 laser system offers enhanced precision, deeper dermal penetration, and reduced thermal diffusion compared with the 30 W, despite delivering equivalent total energy. These findings suggest that higher peak power settings may improve fractional resurfacing procedures' safety and clinical outcomes, particularly in populations with darker skin phototypes.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Medicine > Department of Medicine > Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.