Cited 0 time in
Synthetic-CT 기반 음압 모델이 경두개 집속 초음파 시뮬레이션에 미치는 영향 분석
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 권수영 | - |
| dc.contributor.author | 유지훈 | - |
| dc.contributor.author | 서현 | - |
| dc.date.accessioned | 2025-07-10T05:00:14Z | - |
| dc.date.available | 2025-07-10T05:00:14Z | - |
| dc.date.issued | 2025-06 | - |
| dc.identifier.issn | 1229-0807 | - |
| dc.identifier.issn | 2288-9396 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/79257 | - |
| dc.description.abstract | In transcranial focused ultrasound stimulation simulation studies, CT (Computed Tomography) images or MRI (Magnetic Resonance Imaging) are required. However, obtaining CT data is challenging due to the risks asso- ciated with radiation exposure. This study aims to verify the utility of acoustic pressure models created using Syn- thetic CT (sCT) to determine if they can be an alternative to CT in ultrasound simulations. We obtained CT and MRI from a public dataset to create sCT. A focused ultrasound simulation was performed using a 0.25 MHz single-element transducer. When using the CT model as a reference, the sCT model demonstrated less error and variation in max- imum acoustic pressure than the MRI model. Regarding focal length, the error range for the sCT model was nearly half that of the MRI model. Unlike maximum acoustic pressure, the focal region had a larger error range: 47.1% for the sCT model and 41% for the MRI model. The similarity of maximum acoustic pressure and focal distance between sCT and CT compared to MRI suggests that sCT can be used as a substitute for CT. Future research should consider various frequencies in simulations and conduct them in three dimensions to improve simulation accuracy and increase the amount of data to enable further validation through more accurate statistics. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한의용생체공학회 | - |
| dc.title | Synthetic-CT 기반 음압 모델이 경두개 집속 초음파 시뮬레이션에 미치는 영향 분석 | - |
| dc.title.alternative | Analysis of the Impact of Synthetic-CT Based Acoustic Pressure Models on Transcranial Focused Ultrasound Simulation | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 의공학회지, v.46, no.3, pp 253 - 258 | - |
| dc.citation.title | 의공학회지 | - |
| dc.citation.volume | 46 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 253 | - |
| dc.citation.endPage | 258 | - |
| dc.identifier.kciid | ART003218064 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Synthetic-CT | - |
| dc.subject.keywordAuthor | Acoustic simulation | - |
| dc.subject.keywordAuthor | Acoustic pressure model | - |
| dc.subject.keywordAuthor | Transcranial focused ultrasound | - |
| dc.subject.keywordAuthor | Single-element transducer | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0534
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
