Synthetic-CT 기반 음압 모델이 경두개 집속 초음파 시뮬레이션에 미치는 영향 분석

Full metadata record
DC Field Value Language
dc.contributor.author권수영-
dc.contributor.author유지훈-
dc.contributor.author서현-
dc.date.accessioned2025-07-10T05:00:14Z-
dc.date.available2025-07-10T05:00:14Z-
dc.date.issued2025-06-
dc.identifier.issn1229-0807-
dc.identifier.issn2288-9396-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/79257-
dc.description.abstractIn transcranial focused ultrasound stimulation simulation studies, CT (Computed Tomography) images or MRI (Magnetic Resonance Imaging) are required. However, obtaining CT data is challenging due to the risks asso- ciated with radiation exposure. This study aims to verify the utility of acoustic pressure models created using Syn- thetic CT (sCT) to determine if they can be an alternative to CT in ultrasound simulations. We obtained CT and MRI from a public dataset to create sCT. A focused ultrasound simulation was performed using a 0.25 MHz single-element transducer. When using the CT model as a reference, the sCT model demonstrated less error and variation in max- imum acoustic pressure than the MRI model. Regarding focal length, the error range for the sCT model was nearly half that of the MRI model. Unlike maximum acoustic pressure, the focal region had a larger error range: 47.1% for the sCT model and 41% for the MRI model. The similarity of maximum acoustic pressure and focal distance between sCT and CT compared to MRI suggests that sCT can be used as a substitute for CT. Future research should consider various frequencies in simulations and conduct them in three dimensions to improve simulation accuracy and increase the amount of data to enable further validation through more accurate statistics.-
dc.format.extent6-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한의용생체공학회-
dc.titleSynthetic-CT 기반 음압 모델이 경두개 집속 초음파 시뮬레이션에 미치는 영향 분석-
dc.title.alternativeAnalysis of the Impact of Synthetic-CT Based Acoustic Pressure Models on Transcranial Focused Ultrasound Simulation-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitation의공학회지, v.46, no.3, pp 253 - 258-
dc.citation.title의공학회지-
dc.citation.volume46-
dc.citation.number3-
dc.citation.startPage253-
dc.citation.endPage258-
dc.identifier.kciidART003218064-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorSynthetic-CT-
dc.subject.keywordAuthorAcoustic simulation-
dc.subject.keywordAuthorAcoustic pressure model-
dc.subject.keywordAuthorTranscranial focused ultrasound-
dc.subject.keywordAuthorSingle-element transducer-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seo, Hyeon photo

Seo, Hyeon
IT공과대학 (컴퓨터공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE