Cited 1 time in
Rapid Genotyping of Human Papillomavirus by Desorption Electrospray Ionization Mass Spectrometry
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김신혜 | - |
| dc.contributor.author | 홍선표 | - |
| dc.contributor.author | 조우재 | - |
| dc.contributor.author | 김정권 | - |
| dc.contributor.author | 이태걸 | - |
| dc.contributor.author | 윤소희 | - |
| dc.date.accessioned | 2025-03-20T07:00:11Z | - |
| dc.date.available | 2025-03-20T07:00:11Z | - |
| dc.date.issued | 2017-06 | - |
| dc.identifier.issn | 0253-2964 | - |
| dc.identifier.issn | 1229-5949 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/77475 | - |
| dc.description.abstract | This study describes a new approach to rapidly detecting of human papillomavirus (HPV) DNA using desorption electrospray ionization mass spectrometry (DESI-MS) without sample preparation such as extraction or purification. Our strategy utilizes the ambient ionization mass spectrometry for ionizing and detecting oligonucleotides from restriction fragment mass polymorphism (RFMP) assay, and is to identify which HPV genotype from combinations of multiply charged ions of oligonucleotides. In DESI-MS, the spray solvent system operates at the stage of washing a complex mixture of polymerase chain reaction (PCR) products, so that the oligonucleotides can be detected without sample treatment. The study was verified to rapid diagnosis of cervical cancer by detecting and genotyping of HPV DNA based RFMP assay using DESI-MS. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한화학회 | - |
| dc.title | Rapid Genotyping of Human Papillomavirus by Desorption Electrospray Ionization Mass Spectrometry | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1002/bkcs.11130 | - |
| dc.identifier.scopusid | 2-s2.0-85018748482 | - |
| dc.identifier.bibliographicCitation | Bulletin of the Korean Chemical Society, v.38, no.6, pp 603 - 606 | - |
| dc.citation.title | Bulletin of the Korean Chemical Society | - |
| dc.citation.volume | 38 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 603 | - |
| dc.citation.endPage | 606 | - |
| dc.identifier.kciid | ART002230527 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Desorption electrospray ionization | - |
| dc.subject.keywordAuthor | Mass spectrometry | - |
| dc.subject.keywordAuthor | Human papillomavirus | - |
| dc.subject.keywordAuthor | Restriction fragment mass polymorphism | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.