Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System

Full metadata record
DC Field Value Language
dc.contributor.author한희조-
dc.contributor.author김학진-
dc.contributor.author정대현-
dc.contributor.author조우재-
dc.contributor.author조영열-
dc.contributor.author이공인-
dc.date.accessioned2025-03-20T07:00:10Z-
dc.date.available2025-03-20T07:00:10Z-
dc.date.issued2020-04-
dc.identifier.issn1229-4675-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/77474-
dc.description.abstractThe rapid on-site measurement of hydroponic nutrients allows for the more efficient use of crop fertilizers. This paper reports on the development of an embedded on-site system consisting of multiple ion-selective electrodes (ISEs) for the real-time measurement of the concentrations of macronutrients in hydroponic solutions. The system included a combination of PVC ISEs for the detection of NO3, K, and Ca ions, a cobalt-electrode for the detection of H2PO4, a double-junction reference electrode, a solution container, and a sampling system consisting of pumps and valves. An Arduino Due board was used to collect data and to control the volume of the sample. Prior to the measurement of each sample, a two-point normalization method was employed to adjust the sensitivity followed by an offset to minimize potential drift that might occur during continuous measurement. The predictive capabilities of the NO3 and K ISEs based on PVC membranes were satisfactory, producing results that were in close agreement with the results of standard analyzers (R2 = 0.99). Though the Ca ISE fabricated with Ca ionophore II underestimated the Ca concentration by an average of 55%, the strong linear relationship (R2 > 0.84) makes it possible for the embedded system to be used in hydroponic NO3, K, and Ca sensing. The cobalt-rod-based phosphate electrodes exhibited a relatively high error of 24.7±9.26% in the phosphate concentration range of 45 to 155 mg/L compared to standard methods due to inconsistent signal readings between replicates, illustrating the need for further research on the signal conditioning of cobalt electrodes to improve their predictive ability in hydroponic P sensing.-
dc.format.extent12-
dc.language영어-
dc.language.isoENG-
dc.publisher(사) 한국생물환경조절학회-
dc.titleReal-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System-
dc.title.alternativeISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.12791/KSBEC.2020.29.2.141-
dc.identifier.bibliographicCitation생물환경조절학회지, v.29, no.2, pp 141 - 152-
dc.citation.title생물환경조절학회지-
dc.citation.volume29-
dc.citation.number2-
dc.citation.startPage141-
dc.citation.endPage152-
dc.identifier.kciidART002580699-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor코발트 전극-
dc.subject.keywordAuthor수경 재배-
dc.subject.keywordAuthor이온 선택성 전극-
dc.subject.keywordAuthor다량 원소-
dc.subject.keywordAuthorPVC 멤브레인-
dc.subject.keywordAuthorCobalt electrode-
dc.subject.keywordAuthorHydroponics-
dc.subject.keywordAuthorIon-selective electrode-
dc.subject.keywordAuthorMacronutrients-
dc.subject.keywordAuthorPVC membrane-
Files in This Item
There are no files associated with this item.
Appears in
Collections
농업생명과학대학 > 생물산업기계공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Woo Jae photo

Cho, Woo Jae
농업생명과학대학 (생물산업기계공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE