Detailed Information

Cited 34 time in webofscience Cited 42 time in scopus
Metadata Downloads

Validation testing of an ion-specific sensing and control system for precision hydroponic macronutrient management

Authors
Jung, Dae-HyunKim, Hak-JinCho, Woo-JaePark, Soo HyunYang, Seung-Hwan
Issue Date
Jan-2019
Publisher
Elsevier BV
Keywords
Ion-selective electrode; Macronutrients; Closed hydroponics; Ion-based control; Phosphate sensor; Cobalt electrode
Citation
Computers and Electronics in Agriculture, v.156, pp 660 - 668
Pages
9
Indexed
SCIE
SCOPUS
Journal Title
Computers and Electronics in Agriculture
Volume
156
Start Page
660
End Page
668
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/77472
DOI
10.1016/j.compag.2018.12.025
ISSN
0168-1699
1872-7107
Abstract
Ion-specific nutrient management systems would replace conventional electrical conductivity-based management systems for more efficient maintenance of the concentration of each ion in nutrient solutions for closed hydroponic systems. This study reports on the validation testing of a previously developed ion-specific sensing and control system. Specific objectives were to (1) evaluate the ability of the system to maintain the target concentrations of five macronutrients, i.e., NO3-, PO43-, K+, Ca2+, and Mg-2 ions, required for crop growth in closed hydroponic systems based on both real-time measurement of NO3-, K+, and Ca-2 and the use of a concentration ratio method to replenish Mg2+ and PO43-, and (2) investigate the applicability of a cobalt rod based electrode for hydroponic phosphate sensing. In a lettuce cultivation test conducted with the ebb-and-flow method over 21 days, most of the macronutrient concentrations were successfully maintained at the target levels with RMSE values of 25.2 +/- 9.4, 19.1 +/- 8.1, and 11.5 +/- 6.1 mg-L-1 for NO3-, K +, and Ca2+, respectively. In the case of Mg2+ and PO43- ions replenished in a proportional ratio to the supply of Ca2+ and NO3- ions, respectively, the Mg2+ concentrations were maintained between 18 and 25 mg-L-1 at an almost constant level, whereas the PO43- concentrations increased steadily over time with no clear evidence of plant uptake, implying that the use of a concentration ratio method would not be effective in controlling the concentrations of PO43- in hydroponic solutions. As a phosphate sensor, the cobalt electrodes yielded an RMSE result of 10.9 +/- 7.1% from a comparison of the electrode method and standard analysis when tested in hydroponic lettuce samples taken once a day during the period of lettuce growing, thereby offering the potential for use in hydroponic phosphate sensing.
Files in This Item
There are no files associated with this item.
Appears in
Collections
농업생명과학대학 > 생물산업기계공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Woo Jae photo

Cho, Woo Jae
농업생명과학대학 (생물산업기계공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE