Cited 0 time in
저온냉각수 및 Free Cooling 적용에 의한 데이터센터의 냉방성능 검토
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김유진 | - |
| dc.contributor.author | 하주완 | - |
| dc.contributor.author | 박경순 | - |
| dc.contributor.author | 이건호 | - |
| dc.contributor.author | 송영학 | - |
| dc.date.accessioned | 2022-12-26T13:31:37Z | - |
| dc.date.available | 2022-12-26T13:31:37Z | - |
| dc.date.issued | 2020 | - |
| dc.identifier.issn | 1976-6483 | - |
| dc.identifier.issn | 2586-0666 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/7521 | - |
| dc.description.abstract | The size and number of internet data center (IDC) has been growing rapidly as IT demand has increased recently. IDC needs 10 times as much energy as regular office buildings, there are problems with global warming and increasing carbon emissions. IDC's cooling energy consumption to maintain the IT equipment environment accounts for about 35% of total energy consumption. Therefore, the use of cooling energy was reviewed through simulation by applying the low cooling water temperature system and the free cooling system in this system. Based on this, cooling performance was analyzed using MLC (Mechanical Load Component) indicators. As a result of the simulation, energy consumption in low cooling water temperatures decreased by 8% compared to normal water-cooling systems, while WSE (Water Side Economizer) and ASE (Air Side Economizer) decreased by 26% and 32%, respectively. Since the MLC of conventional water-cooled system was 0.13 which is lower than Incheon's maximum allowable value of 0.18. As a result of the MLC analysis, it was determined that the cooling system was properly designed. The cooling energy usage showed a significant reduction rate in the order of low cooling water temperature, WSE, and ASE, and the ASE was the most efficient operation with 26.3%. | - |
| dc.format.extent | 12 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국건축친환경설비학회 | - |
| dc.title | 저온냉각수 및 Free Cooling 적용에 의한 데이터센터의 냉방성능 검토 | - |
| dc.title.alternative | Energy Evaluation of Data Center with Low Cooling Water Temperature and Free Cooling | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.22696/jkiaebs.20200036 | - |
| dc.identifier.bibliographicCitation | 한국건축친환경설비학회 논문집, v.14, no.5, pp 427 - 438 | - |
| dc.citation.title | 한국건축친환경설비학회 논문집 | - |
| dc.citation.volume | 14 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 427 | - |
| dc.citation.endPage | 438 | - |
| dc.identifier.kciid | ART002640033 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | IDC | - |
| dc.subject.keywordAuthor | MLC | - |
| dc.subject.keywordAuthor | Free cooling | - |
| dc.subject.keywordAuthor | Low cooling water temperature | - |
| dc.subject.keywordAuthor | Annual energy | - |
| dc.subject.keywordAuthor | 데이터센터 | - |
| dc.subject.keywordAuthor | MLC | - |
| dc.subject.keywordAuthor | 프리쿨링 | - |
| dc.subject.keywordAuthor | 저온냉각수 | - |
| dc.subject.keywordAuthor | 연간에너지 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
