Cited 0 time in
인덕터 집적 평면 변압기의 누설 인덕턴스 계산
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 강정철 | - |
| dc.contributor.author | 정세교 | - |
| dc.date.accessioned | 2024-12-17T06:30:17Z | - |
| dc.date.available | 2024-12-17T06:30:17Z | - |
| dc.date.issued | 2024-12 | - |
| dc.identifier.issn | 1229-2214 | - |
| dc.identifier.issn | 2288-6281 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/75081 | - |
| dc.description.abstract | The design and fabrication of magnetic components is one of the most important issues in realizing high-density switching power converters. An integrated magnetics (IM) technique has been used to reduce the size and cost of the magnetic components. In this technique, a leakage inductance can be used as a series inductor connected to the transformer for applications using resonant techniques, such as LLC resonant converter and other zero-voltage switching converters. The calculation of the leakage inductance is required to accurately control the value of the inductance in designing an IM device. This paper describes the calculation of the leakage inductance for the inductor integrated planar transformer used for the high-density LLC resonant converter. The leakage fluxes through the leakage layer is first considered to calculate the biggest part of the leakage inductance. The windings and insulators are also considered to improve calculation accuracy under the uneven number of windings for the PCB layer. Leakage inductance is calculated using magnetic energy equation and equivalent magnetic circuit. Experimental results are provided to verify the effectiveness of the proposed calculation method. | - |
| dc.format.extent | 9 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 전력전자학회 | - |
| dc.title | 인덕터 집적 평면 변압기의 누설 인덕턴스 계산 | - |
| dc.title.alternative | Leakage Inductance Calculation of Inductor Integrated Planar Transformer | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 전력전자학회 논문지, v.29, no.6, pp 510 - 518 | - |
| dc.citation.title | 전력전자학회 논문지 | - |
| dc.citation.volume | 29 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 510 | - |
| dc.citation.endPage | 518 | - |
| dc.identifier.kciid | ART003144733 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Integrated magnetics | - |
| dc.subject.keywordAuthor | Leakage inductance | - |
| dc.subject.keywordAuthor | Resonant converter | - |
| dc.subject.keywordAuthor | Leakage layer | - |
| dc.subject.keywordAuthor | Magnetic sheet | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.