Detailed Information

Cited 1 time in webofscience Cited 3 time in scopus
Metadata Downloads

Harmonic Current Injection Control Algorithm for Narrowing the Switching Frequency Range in CrM Totem-Pole PFC

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Hae-Chan-
dc.contributor.authorJi, Min-Woo-
dc.contributor.authorKim, Dong-Joong-
dc.contributor.authorLee, Gi-Young-
dc.contributor.authorKim, Rae-Young-
dc.date.accessioned2024-12-03T08:00:38Z-
dc.date.available2024-12-03T08:00:38Z-
dc.date.issued2025-02-
dc.identifier.issn0885-8993-
dc.identifier.issn1941-0107-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/74721-
dc.description.abstractPower factor correction (PFC) converters are utilized extensively across various applications, and therefore, developing customized control algorithms is essential to meet the diverse operational requirements. In critical conduction mode (CrM) totem-pole PFC technology, introducing harmonic currents into a command signal is a viable approach for enhancing the performance of the PFC converter. However, this approach suffers from the risk of exceeding the planned harmonic current injection because of external interference. To overcome this issue, this study introduces a novel control algorithm that incorporates a harmonic injection technique to maintain stable performance despite disturbances or load variations. This algorithm uses Fourier analysis to precisely calculate each harmonic component and employs proportional-integral (PI) compensation along with feedforward corrections method to inject harmonic currents accurately in alignment with theoretical expectations. The efficacy of the proposed algorithm is validated through experiments conducted on a 350 W totem-pole PFC converter prototype under various load conditions. A comparison between the harmonic injection commands determined through a power analyzer and the actual measurements revealed that control was maintained within an error margin of 4.5%, demonstrating that harmonic control was effectively operational even under load variations. © 1986-2012 IEEE.-
dc.format.extent13-
dc.language영어-
dc.language.isoENG-
dc.publisherInstitute of Electrical and Electronics Engineers-
dc.titleHarmonic Current Injection Control Algorithm for Narrowing the Switching Frequency Range in CrM Totem-Pole PFC-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1109/TPEL.2024.3488788-
dc.identifier.scopusid2-s2.0-85208361180-
dc.identifier.wosid001378125700019-
dc.identifier.bibliographicCitationIEEE Transactions on Power Electronics, v.40, no.2, pp 2958 - 2970-
dc.citation.titleIEEE Transactions on Power Electronics-
dc.citation.volume40-
dc.citation.number2-
dc.citation.startPage2958-
dc.citation.endPage2970-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.subject.keywordAuthorCritical conduction mode control-
dc.subject.keywordAuthorFeedback control algorithm-
dc.subject.keywordAuthorFourier analysis-
dc.subject.keywordAuthorHarmonic injection-
dc.subject.keywordAuthorProportional-integral compensation-
dc.subject.keywordAuthorTotem-pole PFC-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Gi Young photo

Lee, Gi Young
IT공과대학 (전기공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE