Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

AUTOMATED DRIFT COMPENSATION SYSTEM FOR ELECTRICAL CONDUCTIVITY AND PH PROBES IN HYDROPONIC SYSTEMS

Authors
Cho, Woo-JaeKim, Dong-WookKim, Hak-JinGang, MinseokJung, DaehyunYang, Seung HwanPark, Soo Hyun
Issue Date
Sep-2024
Publisher
American Society of Agricultural and Biological Engineers
Keywords
Automation; Compensation; Drift; EC; Hydroponics; pH
Citation
Journal of the ASABE, v.67, no.5, pp 1203 - 1215
Pages
13
Indexed
SCIE
SCOPUS
Journal Title
Journal of the ASABE
Volume
67
Number
5
Start Page
1203
End Page
1215
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/74531
DOI
10.13031/ja.15603
ISSN
2769-3295
2769-3287
Abstract
In hydroponic systems, the nutrient solutions are dispensed based on pH and electrical conductivity (EC) to ensure that the nutrient components in the solution are optimal for crop growth. However, the pH and EC probes may exhibit signal drifts when immersed in the solution for a considerable period, which deteriorate the measurement accuracy and the nutrient and water use efficiency. Notably, the existing hydroponic systems require manual calibration of the pH and EC probes and do not provide any information regarding their accuracy. Consequently, faults in the probes are challenging to detect. In this study, two types of automated drift compensation systems for EC and pH probes, based on one- and two-point normalization, were developed to accurately monitor changes in the pH and EC values in hydroponic solutions and enhance sensor management. The proposed framework can provide information regarding the drifts of the pH and EC probes through automated normalization solution measurements. The effectiveness of the developed system in scenarios involving plant growth with open and closed hydroponics was evaluated through comparison with a standard method involving sampling and laboratory analysis. The results indicated that the one-point normalization strategy had a simple structure and was effective in compensating drifted offsets of sensors. A two-point normalization strategy could effectively predict the sensor drifts as well as variations in the sensitivities, which could be used in the compensation processes. Application of the one-point normalization-based system increased the accuracy of the EC and pH measurements, with root mean square errors decreasing from 50 to 28.5 μS∙cm-1 and 0.43 to 0.17 pH in the open hydroponic systems and from 68.7 to 38.3 μS∙cm-1 and 0.15 to 0.11 pH in the closed systems, respectively. The two-point normalization-based system decreased the RMSEs from 44.6 to 33.4 μS∙cm-1 and 0.55 to 0.20 pH for the EC and pH measurements, respectively. In addition, the decreased slope and coefficient of determination in the linear regression according to the system application proved the system can compensate for the drifts of the EC and pH probes. The proposed system provided accurate EC and pH measurements and sensor status information, promoting more efficient nutrient use and sensor maintenance. © 2024 American Society of Agricultural and Biological Engineers.
Files in This Item
There are no files associated with this item.
Appears in
Collections
농업생명과학대학 > 생물산업기계공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Woo Jae photo

Cho, Woo Jae
농업생명과학대학 (생물산업기계공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE