Cited 0 time in
Straightforward, safe, and efficient interlocking screw insertion during intramedullary nailing using a Steinmann pin and hammer: a comparative study
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Deslivia, Maria Florencia | - |
| dc.contributor.author | Kim, Hee-June | - |
| dc.contributor.author | Kim, Sung Hun | - |
| dc.contributor.author | Lee, Suk-Joong | - |
| dc.date.accessioned | 2024-12-03T05:00:35Z | - |
| dc.date.available | 2024-12-03T05:00:35Z | - |
| dc.date.issued | 2024-07 | - |
| dc.identifier.issn | 2234-3180 | - |
| dc.identifier.issn | 2234-2591 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/74111 | - |
| dc.description.abstract | Objectives: Accurately targeting distal nail holes and placing distal interlocking screws pose challenges during intramedullary nailing. This study proposes a straightforward technique for distal locking screw insertion using a Steinmann pin, eliminating the need to reposition the pin or drill bit. Methods: We utilized 18 Sawbones femur models and intramedullary femur nails. A first-year resident created two distal locking holes on each model, employing both the conventional freehand technique and a novel method involving a Steinmann pin and hammer under image intensification. These techniques were evaluated based on three parameters: (1) the time required to create distal locking holes, measured from the moment the pin was positioned at the center of the hole until the far cortex was drilled through the interlocking hole; (2) the radiation dose (in mrem/h), as estimated with a personal gamma radiation dosimeter; and (3) the number of failures, defined as the creation of more than one hole in the near and far cortex. Results: The new technique was associated with a lower radiation dose (P=0.0268) and fewer failures (P=0.0367) than the conventional approach. Additionally, the time required to establish distal holes was shorter using the new technique compared to the conventional method (P=0.0217). Conclusion: The creation of distal interlocking holes with a Steinmann pin and hammer is accurate, efficient, and cost-effective. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | EWHA Womans University School of Medicine | - |
| dc.title | Straightforward, safe, and efficient interlocking screw insertion during intramedullary nailing using a Steinmann pin and hammer: a comparative study | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.7910/DVN/ND7IIK | - |
| dc.identifier.wosid | 001301917800014 | - |
| dc.identifier.bibliographicCitation | EWHA Medical Journal, v.47, no.3 | - |
| dc.citation.title | EWHA Medical Journal | - |
| dc.citation.volume | 47 | - |
| dc.citation.number | 3 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | esci | - |
| dc.relation.journalResearchArea | General & Internal Medicine | - |
| dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
| dc.subject.keywordPlus | RADIATION-EXPOSURE | - |
| dc.subject.keywordPlus | DISTAL LOCKING | - |
| dc.subject.keywordPlus | SURGEON | - |
| dc.subject.keywordAuthor | Bone screws | - |
| dc.subject.keywordAuthor | Cost-benefit analysis | - |
| dc.subject.keywordAuthor | Femur | - |
| dc.subject.keywordAuthor | Fracture | - |
| dc.subject.keywordAuthor | Radiation dosage | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.