| dc.description.abstract | To develope a greenhouse fog cooling system to control the temperature and relative humidity simultaneously to the target value, a theoretical analysis and experiments were done. The control process includes the measuring of environmental variables, setting and coding of the water and heat balance equations to maintain the target temperature and relative humidity in greenhouse, calculating of the open level of the greenhouse roof window that governs the natural ventilation and spray water quantity, and operating of the motor to open/close the roof window and pump to spray for water. The study results were shown to be very good because the average air temperature in the greenhouse was kept to be about 28.2°C with the standard deviation of about 0.37°C compared to the target temperature of 28°C and the average relative humidity was about 75.2% compared to the target relative humidity was 75% during the experiments. Journal of the Korean Solar Energy 32 Society Vol. 36, No. 5, 2016 The average outside relative humidity was about 41.0% and the average outside temperature was 27.2°C with the standard deviation of about 0.54°C. The average solar intensity in the greenhouse was 712.9 W. The wind velocity of outside greenhouse was 0.558 m/s with the standard deviation of 0.46 m/s. | - |
| dc.format.extent | 20 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국태양에너지학회 | - |
| dc.title | 자연환기량과 포그분무량 조절에 의한 온실온습도의 동시제어 기법 연구 | - |
| dc.title.alternative | A Study on the Control of the Temperature and Relative Humidity in Greenhouse by Adjusting the Amount of Natural Ventilation and Fog Spray Quantity | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국태양에너지학회 논문집, v.36, no.5, pp 31 - 50 | - |
| dc.citation.title | 한국태양에너지학회 논문집 | - |
| dc.citation.volume | 36 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 31 | - |
| dc.citation.endPage | 50 | - |
| dc.identifier.kciid | ART002162096 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | 포그냉방(Fog cooling) | - |
| dc.subject.keywordAuthor | 천창제어(Roof window control) | - |
| dc.subject.keywordAuthor | 환기율(Ventilation rate) | - |
| dc.subject.keywordAuthor | 온실온도(Greenhouse temperature) | - |
| dc.subject.keywordAuthor | 온실습도(Greenhouse humidity) | - |
| dc.subject.keywordAuthor | 제어시스템(Control system) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.