Method for Determining Dissipation Factor of Capacitors Without Reference Capacitor at Voltages up to 1 kV
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Jung, Jae Kap | - |
| dc.contributor.author | Kim, Kyu-Tae | - |
| dc.contributor.author | Ryu, Kwon Sang | - |
| dc.contributor.author | Chung, Ki Soo | - |
| dc.date.accessioned | 2024-12-03T00:00:44Z | - |
| dc.date.available | 2024-12-03T00:00:44Z | - |
| dc.date.issued | 2019-01 | - |
| dc.identifier.issn | 1975-0102 | - |
| dc.identifier.issn | 2093-7423 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/73237 | - |
| dc.description.abstract | Objectives and design This paper describes a method to determine absolutely the dissipation factor (DF) of a capacitor connected with resistor in series that doesn't depend on any reference capacitor with a known DF. Materials and methods The method was applied to calibrate the DFs for two capacitor-resistor boxes that had DF ranges of 1 x 10(-5) to 1 x 10(-2) (C-R connecting box A) and 5 x 10(-6) to 5 x 10(-3) (C-R connecting box B), together with uncertainty estimation. The principle of the absolute determination is based on "elimination" of the DF of a reference capacitor by subtracting DF readings from two successive measurements. Results This method was applied to the calibration of DF in the range 5 x 10(-6) to 1 x 10(-2) at voltages up to 1 kV. Results obtained using this method were confirmed by comparing them with DF obtained using different methods Conclusions The developed DF standard could be used to calibrate DF for commercial capacitors and DF methods. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | KOREAN INST ELECTR ENG | - |
| dc.title | Method for Determining Dissipation Factor of Capacitors Without Reference Capacitor at Voltages up to 1 kV | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1007/s42835-018-00007-7 | - |
| dc.identifier.scopusid | 2-s2.0-85067693663 | - |
| dc.identifier.wosid | 000459450800035 | - |
| dc.identifier.bibliographicCitation | JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, v.14, no.1, pp 371 - 376 | - |
| dc.citation.title | JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY | - |
| dc.citation.volume | 14 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 371 | - |
| dc.citation.endPage | 376 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002432461 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.subject.keywordPlus | FREQUENCY | - |
| dc.subject.keywordPlus | CALIBRATION | - |
| dc.subject.keywordPlus | RESISTOR | - |
| dc.subject.keywordAuthor | Capacitance bridge | - |
| dc.subject.keywordAuthor | Measurement uncertainty | - |
| dc.subject.keywordAuthor | Dissipation factor (DF) standard | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.