Cited 0 time in
Automated Cold Volume Calibration of Temperature Variation in Cryogenic Hydrogen Isotope Sorption Isotherm
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Jaewoo | - |
| dc.contributor.author | Oh, Hyunchul | - |
| dc.date.accessioned | 2024-12-02T23:30:48Z | - |
| dc.date.available | 2024-12-02T23:30:48Z | - |
| dc.date.issued | 2019-05 | - |
| dc.identifier.issn | 1225-0562 | - |
| dc.identifier.issn | 2287-7258 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/72967 | - |
| dc.description.abstract | The gas adsorption isotherm requires accurate measurement for the analysis of porous materials and is used as an index of surface area, pore distribution, and adsorption amount of gas. Basically, adsorption isotherms of porous materials are measured conventionally at 77K and 87K using liquid nitrogen and liquid argon. The cold volume calibration in this conventional method is done simply by splitting a sample cell into two zones (cold and warm volumes) by controlling the level sensor in a Dewar filled with liquid nitrogen or argon. As a result, BET measurement for textural properties is mainly limited to liquefied gases (i.e. N-2 or Ar) at atmospheric pressure. In order to independently investigate other gases (e.g. hydrogen isotopes) at cryogenic temperature, a novel temperature control system in the sample cell is required, and consequently cold volume calibration at various temperatures becomes more important. In this study, a cryocooler system is installed in a commercially available BET device to control the sample cell temperature, and the automated cold volume calibration method of temperature variation is introduced. This developed calibration method presents a reliable and reproducible method of cryogenic measurement for hydrogen isotope separation in porous materials, and also provides large flexibility for evaluating various other gases at various temperature. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | MATERIALS RESEARCH SOC KOREA | - |
| dc.title | Automated Cold Volume Calibration of Temperature Variation in Cryogenic Hydrogen Isotope Sorption Isotherm | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3740/MRSK.2019.29.5.336 | - |
| dc.identifier.scopusid | 2-s2.0-85066819867 | - |
| dc.identifier.wosid | 000482739100010 | - |
| dc.identifier.bibliographicCitation | KOREAN JOURNAL OF MATERIALS RESEARCH, v.29, no.5, pp 336 - 341 | - |
| dc.citation.title | KOREAN JOURNAL OF MATERIALS RESEARCH | - |
| dc.citation.volume | 29 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 336 | - |
| dc.citation.endPage | 341 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002468934 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | esci | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Materials Science | - |
| dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
| dc.subject.keywordPlus | SURFACE-AREA | - |
| dc.subject.keywordPlus | GAS-ADSORPTION | - |
| dc.subject.keywordPlus | NITROGEN | - |
| dc.subject.keywordAuthor | calibration method | - |
| dc.subject.keywordAuthor | cryogenic measurements | - |
| dc.subject.keywordAuthor | cold volume and temperature calibrations | - |
| dc.subject.keywordAuthor | accuracy | - |
| dc.subject.keywordAuthor | adsorption isotherm | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.