Detailed Information

Cited 19 time in webofscience Cited 20 time in scopus
Metadata Downloads

Wide-Field Swept-Source Optical Coherence Tomography Analysis of Interocular Symmetry of Choroidal Thickness in Healthy Young Individuals

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Min-Su-
dc.contributor.authorLim, Hyung-Bin-
dc.contributor.authorLee, Woo-Hyuk-
dc.contributor.authorKim, Kyeung-Min-
dc.contributor.authorNam, Ki Yup-
dc.contributor.authorKim, Jung-Yeul-
dc.date.accessioned2024-12-02T23:00:55Z-
dc.date.available2024-12-02T23:00:55Z-
dc.date.issued2021-03-
dc.identifier.issn0146-0404-
dc.identifier.issn1552-5783-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/72822-
dc.description.abstractPURPOSE. The purpose of this paper was to study the bilateral choroidal thickness (CT) symmetry and differences in healthy individuals using wide-field swept-source optical coherence tomography (SS-OCT). METHODS. All participants underwent a wide-field 16-mm 1-line scan using SS-OCT. CTs were measured at the following 12 points: 3 points at 900 mu m, 1800 mu m, and 2700 mu m away from the nasal optic disc margin (nasal peripapillary area), 1 point at the subfovea, 6 points at 900 mu m, 1800 mu m, and 2700 mu m away from the subfovea to the nasal and temporal areas (macular area), and 2 peripheral points at 2700 and 5400 mu m from temporal point 3 (peripheral area). Bilateral CTs were measured; their correlations and differences in the corresponding regions were analyzed. RESULTS. There were no statistically significant differences in CTs between the right and left eyes in all corresponding areas (all P > 0.05); they all showed significant positive correlation coefficients (r) (all P < 0.001). However, the nasal peripapillary and peripheral areas had relatively low correlation coefficients, compared to the macular areas. In addition, the bilateral CT differences were 32.60 +/- 25.80 mu m in the macular area, 40.67 +/- 30.58 mu m in the nasal peripapillary area, and 56.03 +/- 45.73 mu m in the peripheral area (all P < 0.001). CONCLUSIONS. Overall, the CTs of each region were bilaterally symmetrical. However, the differences in CTs increased from the center to the periphery, which indicated that the anatomic variation of the nasal peripapillary and peripheral choroid was greater than that of the macula.-
dc.language영어-
dc.language.isoENG-
dc.publisherASSOC RESEARCH VISION OPHTHALMOLOGY INC-
dc.titleWide-Field Swept-Source Optical Coherence Tomography Analysis of Interocular Symmetry of Choroidal Thickness in Healthy Young Individuals-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1167/iovs.62.3.5-
dc.identifier.scopusid2-s2.0-85102427406-
dc.identifier.wosid000639521500005-
dc.identifier.bibliographicCitationINVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, v.62, no.3-
dc.citation.titleINVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE-
dc.citation.volume62-
dc.citation.number3-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.subject.keywordPlusAXIAL LENGTH-
dc.subject.keywordPlusEYES-
dc.subject.keywordPlusOCT-
dc.subject.keywordPlusPOPULATION-
dc.subject.keywordPlusASYMMETRY-
dc.subject.keywordPlusDENSITY-
dc.subject.keywordPlusPROFILE-
dc.subject.keywordPlusMYOPIA-
dc.subject.keywordPlusAGE-
dc.subject.keywordAuthorchoroidal thickness-
dc.subject.keywordAuthorinterocular symmetry-
dc.subject.keywordAuthorwide-field swept-source optical coherence tomography-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE