Detailed Information

Cited 5 time in webofscience Cited 6 time in scopus
Metadata Downloads

Long-term repeatability of peripapillary optical coherence tomography angiography measurements in healthy eyes

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Woo Hyuk-
dc.contributor.authorLee, Min-Woo-
dc.contributor.authorKim, Min-Su-
dc.contributor.authorRyu, Cheon Kuk-
dc.contributor.authorKim, Jung-Yeul-
dc.date.accessioned2024-12-02T23:00:53Z-
dc.date.available2024-12-02T23:00:53Z-
dc.date.issued2021-12-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/72777-
dc.description.abstractThis is a prospective observational study to establish the short- and long-term repeatability of measurements of peripapillary optical coherence tomography angiography (OCTA) parameters in healthy eyes and identify factors affecting long-term repeatability. We enrolled 84 healthy eyes. Participants with a history of any ophthalmic disease (except high myopia) or intraocular surgery were excluded from the study. An experienced examiner performed OCTA using disc-centered 6 x 6 mm scans. All examinations were conducted twice at 5-min intervals at the initial visit and repeated at least 6 months later. For short-term repeatability, the coefficient of variation (CV) was 2.94-4.22% and the intraclass correlation coefficient (ICC) was 0.840-0.934. For long-term repeatability, the CV was 2.73-3.84% and the ICC was 0.737-0.934. Multivariate analyses showed that the axial length (AL) (B = 0.970; p = 0.002) and mean signal strength (SS) (B = - 2.028; p < 0.001) significantly affected long-term repeatability. Measurements of peripapillary OCTA parameters exhibited excellent short-term and good long-term repeatability in healthy individuals. The mean SS and AL affected long-term repeatability and should be considered while interpreting peripapillary OCTA images.-
dc.language영어-
dc.language.isoENG-
dc.publisherNATURE PORTFOLIO-
dc.titleLong-term repeatability of peripapillary optical coherence tomography angiography measurements in healthy eyes-
dc.typeArticle-
dc.publisher.location독일-
dc.identifier.doi10.1038/s41598-021-03469-4-
dc.identifier.scopusid2-s2.0-85121024408-
dc.identifier.wosid000729935300083-
dc.identifier.bibliographicCitationSCIENTIFIC REPORTS, v.11, no.1-
dc.citation.titleSCIENTIFIC REPORTS-
dc.citation.volume11-
dc.citation.number1-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.subject.keywordPlusVESSEL DENSITY-MEASUREMENTS-
dc.subject.keywordPlusSIZE-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE