Cited 0 time in
Performance of the Belle II calorimeter trigger system at the SuperKEKB Phase 3 run
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Unno, Y. | - |
| dc.contributor.author | Kim, C. H. | - |
| dc.contributor.author | Cho, H. E. | - |
| dc.contributor.author | Cheon, B. G. | - |
| dc.contributor.author | Kim, S. H. | - |
| dc.contributor.author | Lee, I. S. | - |
| dc.contributor.author | Kim, Y. J. | - |
| dc.contributor.author | Jang, E. J. | - |
| dc.contributor.author | Choi, S-K | - |
| dc.contributor.author | Iwasaki, Y. | - |
| dc.contributor.author | Koga, T. | - |
| dc.contributor.author | Nakazawa, H. | - |
| dc.contributor.author | Kuzmin, A. | - |
| dc.date.accessioned | 2024-12-02T22:00:59Z | - |
| dc.date.available | 2024-12-02T22:00:59Z | - |
| dc.date.issued | 2020-09 | - |
| dc.identifier.issn | 1748-0221 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/72338 | - |
| dc.description.abstract | The Belle II experiment at the SuperKEKB electron-positron collider began physics data-taking in 2019 with full detectors. The main goal of the Belle II is to search for new physics beyond the Standard Model in heavy flavor decays and Dark sector. In order to select events of interest efficiently under severe beam background environment from higher instantaneous luminosity run than the KEKB collider, we have upgraded a real-time hardware trigger system using the CsI(Tl) electromagnetic calorimeter. In this report, performance of the calorimeter trigger system under SuperKEKB Phase 3 operation is described. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Physics | - |
| dc.title | Performance of the Belle II calorimeter trigger system at the SuperKEKB Phase 3 run | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1088/1748-0221/15/09/C09060 | - |
| dc.identifier.scopusid | 2-s2.0-85092579534 | - |
| dc.identifier.wosid | 000577272600060 | - |
| dc.identifier.bibliographicCitation | Journal of Instrumentation, v.15, no.9 | - |
| dc.citation.title | Journal of Instrumentation | - |
| dc.citation.volume | 15 | - |
| dc.citation.number | 9 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.subject.keywordAuthor | Trigger algorithms | - |
| dc.subject.keywordAuthor | Calorimeters | - |
| dc.subject.keywordAuthor | Trigger concepts and systems (hardware and software) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.