Cited 0 time in
Considerations in Selecting a Fitting a Function for Film Dosimetry in Radiation Therapy
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Hwang, Ui-Jung | - |
| dc.contributor.author | Kim, Ki Hwan | - |
| dc.contributor.author | Lim, Young Kyung | - |
| dc.contributor.author | Kim, Haksoo | - |
| dc.contributor.author | Choi, Sang Hyoun | - |
| dc.contributor.author | Min, Byung Jun | - |
| dc.contributor.author | Jeong, Hojin | - |
| dc.contributor.author | Rah, Jeong Eun | - |
| dc.date.accessioned | 2024-12-02T22:00:56Z | - |
| dc.date.available | 2024-12-02T22:00:56Z | - |
| dc.date.issued | 2020-07 | - |
| dc.identifier.issn | 0374-4884 | - |
| dc.identifier.issn | 1976-8524 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/72296 | - |
| dc.description.abstract | Although many technologies, such as an electronic portal imaging device, a software-based quality assurance system, an ion chamber array,etc., have been developed for the purpose of quality assurance of radiotherapy planning, radiochromic film is still one of the most reliable technologies and is being widely used. In particular, compared with other technologies, EBT3 film has unique advantages, including its unlimited spatial resolution, relatively small volume and waterproof quality, which means it can be used inside the patient's body. The main obstacle to using EBT3 film is that various equations have to be used in the calibration process, which makes it very sensitive to the results. The manufacturer provides a fitting function, but many software programs and researchers use their own functions. In this study, some functions normally used for calibrating EBT3 films are compared by analyzing a couple of characteristics in the course of fitting the function to the measured values. Although our study shows the lack of a suitable fitting function that works well in every situation, it can provide valuable insight into selecting suitable functions for fitting in a clinical setting. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국물리학회 | - |
| dc.title | Considerations in Selecting a Fitting a Function for Film Dosimetry in Radiation Therapy | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3938/jkps.77.94 | - |
| dc.identifier.scopusid | 2-s2.0-85087747766 | - |
| dc.identifier.wosid | 000548539000015 | - |
| dc.identifier.bibliographicCitation | Journal of the Korean Physical Society, v.77, no.1, pp 94 - 101 | - |
| dc.citation.title | Journal of the Korean Physical Society | - |
| dc.citation.volume | 77 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 94 | - |
| dc.citation.endPage | 101 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART002608817 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
| dc.subject.keywordPlus | PORTAL IMAGING DEVICE | - |
| dc.subject.keywordPlus | FLAT-BED SCANNER | - |
| dc.subject.keywordPlus | RADIOCHROMIC FILM | - |
| dc.subject.keywordPlus | EBT FILM | - |
| dc.subject.keywordPlus | SENSITOMETRIC CURVES | - |
| dc.subject.keywordPlus | PHOTON | - |
| dc.subject.keywordPlus | MODEL | - |
| dc.subject.keywordPlus | CALIBRATION | - |
| dc.subject.keywordPlus | ELECTRON | - |
| dc.subject.keywordPlus | PROTOCOL | - |
| dc.subject.keywordAuthor | Radiation therapy | - |
| dc.subject.keywordAuthor | Quality assurance | - |
| dc.subject.keywordAuthor | EBT3 film | - |
| dc.subject.keywordAuthor | OD to dose calibration | - |
| dc.subject.keywordAuthor | Curve fitting | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.