Detailed Information

Cited 14 time in webofscience Cited 14 time in scopus
Metadata Downloads

Long-term repeatability of optical coherence tomography angiography parameters in healthy eyes

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Min-Woo-
dc.contributor.authorNam, Ki-Yup-
dc.contributor.authorLim, Hyung-Bin-
dc.contributor.authorKoo, Hyung-Moon-
dc.contributor.authorShin, Yong-Il-
dc.contributor.authorKim, Jung-Yeul-
dc.date.accessioned2024-12-02T21:30:53Z-
dc.date.available2024-12-02T21:30:53Z-
dc.date.issued2020-02-
dc.identifier.issn1755-375X-
dc.identifier.issn1755-3768-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/71902-
dc.description.abstractPurpose To determine the long-term repeatability of optical coherence tomography angiography (OCTA) parameters in normal eyes. Methods We prospectively enrolled 104 normal eyes. Participants were divided into three groups based on differences in the signal strength (SS) of OCTA scans obtained at two visits at least 6 months apart: group 1, SS difference = 2; group 2, 1; group 3, 0. We measured a foveal centred scan area of 3 x 3 mm pattern. All measurements were performed twice at 5-min intervals at the initial visit. The second measurements were performed at least 6 months later. Results In short-term vessel density (VD) repeatability, the coefficient of variation (CV) ranged from 3.89% to 8.10% and the intraclass correlation coefficient (ICC) ranged from 0.785 to 0.941. In terms of long-term repeatability, the CV was 5.39-12.62% and the ICC was 0.598-0.867. In group 1, the ICCs of the inner and full VDs were 0.194 and 0.221, respectively. In groups 2 and 3, the ICCs of the inner and full VDs were 0.611 and 0.603, and 0.763 and 0.765, respectively. The central VDs of all groups had high CV besides high ICC. Conclusions Optical coherence tomography angiography parameters showed good short-term and reasonable long-term repeatability in normal individuals. The differences in SSs between measurements affected such repeatability, so physicians should query the reliability of OCTA parameters when the differences in SS are 2 or more even when the SS is high.-
dc.language영어-
dc.language.isoENG-
dc.publisherWiley-Blackwell-
dc.titleLong-term repeatability of optical coherence tomography angiography parameters in healthy eyes-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1111/aos.14203-
dc.identifier.scopusid2-s2.0-85072175084-
dc.identifier.wosid000486340500001-
dc.identifier.bibliographicCitationActa Ophthalmologica, v.98, no.1, pp E36 - E42-
dc.citation.titleActa Ophthalmologica-
dc.citation.volume98-
dc.citation.number1-
dc.citation.startPageE36-
dc.citation.endPageE42-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.subject.keywordPlusVESSEL DENSITY-MEASUREMENTS-
dc.subject.keywordPlusREPRODUCIBILITY-
dc.subject.keywordAuthoroptical coherence tomography angiography-
dc.subject.keywordAuthorrepeatability-
dc.subject.keywordAuthorvessel density-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Altmetrics

Total Views & Downloads

BROWSE