Research on a Plan of Free Cooling Operation Control for the Efficiency Improvement of a Water-Side Economizer

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Yu-Jin-
dc.contributor.authorKim, Kwang-Hee-
dc.contributor.authorHa, Ju-Wan-
dc.contributor.authorSong, Young-Hak-
dc.date.accessioned2024-07-10T08:30:24Z-
dc.date.available2024-07-10T08:30:24Z-
dc.date.issued2024-06-
dc.identifier.issn1996-1073-
dc.identifier.issn1996-1073-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/71046-
dc.description.abstractThe energy reduction in chillers has been considered an important factor in the energy efficiency improvements of cooling systems, and water-side free cooling is regarded as the key of chiller free cooling technology. Therefore, this research aims to develop a control methodology for the extension of the free cooling operation time in order to improve the efficiency of water cooling-type chillers based on a WSE (water-side economizer) system for a data center and review the proper control conditions through an energy usage analysis of the entire system. The suggested methodology is an increase in the chilled water supply and return temperature according to the increase in the CARH (Computer Room Air Handler) fan air flow and a decrease in the chilled water flow. A case study was conducted according to the application of control through an EnergyPlus simulation. The results of the simulation show that energy usage was reduced by 8.1% under 120% CRAH fan capacity and 100% chilled water flow conditions. When applying the control plan, the free cooling period was extended according to the increased CRAH fan capacity and decreased chilled water flow. However, the increase in the CRAH fan energy must be considered. Also, in the case of a reduction in the chilled water flow, it is necessary to consider a point that can guarantee the cooling treatment heat rate in the heat exchanger.-
dc.language영어-
dc.language.isoENG-
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)-
dc.titleResearch on a Plan of Free Cooling Operation Control for the Efficiency Improvement of a Water-Side Economizer-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/en17122804-
dc.identifier.scopusid2-s2.0-85197245960-
dc.identifier.wosid001256379900001-
dc.identifier.bibliographicCitationEnergies, v.17, no.12-
dc.citation.titleEnergies-
dc.citation.volume17-
dc.citation.number12-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.subject.keywordPlusSIMULATION-
dc.subject.keywordAuthorWSE system-
dc.subject.keywordAuthorcooling energy-
dc.subject.keywordAuthorfree cooling-
dc.subject.keywordAuthorchilled water flow control-
dc.subject.keywordAuthorCRAH fan control-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > School of Architectural Engineering > Journal Articles
공학계열 > 건축공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Young Hak photo

Song, Young Hak
공과대학 (건축공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE