| dc.description.abstract | An external ENTA damper system or steel frame seismic retrofit approach was investigated for historic reinforced concrete (RC) buildings. RC frame specimens were evaluated under cyclic lateral loading to confirm the external retrofit approach. The investigation involved an examination and comparison of hysteresis-based behaviors, such as strength, ductility, and energy dissipation, with the aim of gaining a deeper comprehension of the distinct impacts of external retrofit systems on seismic performance. The experimental findings indicate that the implementation of the external ENTA damper system and steel frame effectively enhanced the stiffness and durability of vulnerable RC moment frames, while maintaining their deformation capacity. The enhancement of the energy-dissipation capacity was achieved by the use of measures to prevent premature failure of the RC beam-column joints. On the basis of the experimental results, the failure mechanism of the RC frame was discussed, considering the shear connection behavior. In order to further validate the experimental results, analytical modeling of the undamaged specimens was carried out using the LS-DYNA program. The test strengths of the frame specimens were evaluated and compared to the anticipated values derived from a simple plastic mechanism. © 2024 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Pergamon Press Ltd. | - |
| dc.title | Analytical and experimental investigation on performance of ENTA damper systems for RC moment frame under cyclic loading | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1016/j.engstruct.2024.118386 | - |
| dc.identifier.scopusid | 2-s2.0-85195823026 | - |
| dc.identifier.wosid | 001255543600001 | - |
| dc.identifier.bibliographicCitation | Engineering Structures, v.314 | - |
| dc.citation.title | Engineering Structures | - |
| dc.citation.volume | 314 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
| dc.subject.keywordPlus | BEAM-COLUMN JOINTS | - |
| dc.subject.keywordPlus | INTERIOR JOINTS | - |
| dc.subject.keywordPlus | STRENGTH | - |
| dc.subject.keywordPlus | MODEL | - |
| dc.subject.keywordPlus | DETERIORATION | - |
| dc.subject.keywordAuthor | Cyclic lateral loading | - |
| dc.subject.keywordAuthor | ENTA damper | - |
| dc.subject.keywordAuthor | RC frame | - |
| dc.subject.keywordAuthor | Shear connection | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.