원적외선 도장 건조용 3상 사이리스터 AC/AC 전력변환시스템의 입력전류 고조파저감 및 온도/전력제어 스위칭기법
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 안혜은 | - |
| dc.contributor.author | 김석은 | - |
| dc.contributor.author | 곽진영 | - |
| dc.contributor.author | 이정인 | - |
| dc.contributor.author | 김태웅 | - |
| dc.date.accessioned | 2024-06-20T00:30:19Z | - |
| dc.date.available | 2024-06-20T00:30:19Z | - |
| dc.date.issued | 2024-06 | - |
| dc.identifier.issn | 1229-2214 | - |
| dc.identifier.issn | 2288-6281 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/70832 | - |
| dc.description.abstract | A direct thyristor AC/AC converter is configured as a 3-phase 4-wire type to be used in an eco-friendly and efficient far-infrared paint drying system. Additionally, the zero-crossing-based switching scheme is proposed in the paper for the output power control in detail according to temperature-power relationship. A direct thyristor AC/AC converter with a simple and economical converter connection structure is suitable for this application. The phase control for thyristor AC/AC converter has a negative impact on the power system by producing harmonic currents depending on the conduction angle adjustment, and a problem of incurring additional costs exists due to the application of filters. Zero-crossing control of a conventional 3-phase 3-wire thyristor AC/AC converter has the disadvantage of large range of change in output power. To minimize this problem, the paper introduces the topology of a 3-phase 4-wire thyristor AC/AC converter based on zero-crossing control scheme to minimize the generation of harmonics in the input current and segment the output power. PLL algorithm is applied to detect the phase information of the grid voltage, and a power calculation method based on d-q coordinate transformation considering the absent current generated by the proposed switching combination is presented. Following a switching combination control technique based on zero crossing control that can be controlled according to the temperature/power relationship, arbitrary 3-phase, 2-phase, 1-phase operation and no-output states are controlled for logical feasibility through PSIM simulation analysis. The effectiveness is also proven by confirming the harmonic distortion reduction through experimentation. | - |
| dc.format.extent | 10 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 전력전자학회 | - |
| dc.title | 원적외선 도장 건조용 3상 사이리스터 AC/AC 전력변환시스템의 입력전류 고조파저감 및 온도/전력제어 스위칭기법 | - |
| dc.title.alternative | Input Current Harmonic Reduction and Temperature/Power Control Switching Scheme of 3-Phase Thyristor AC/AC Converter for Infrared Paint Drying | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 전력전자학회 논문지, v.29, no.3, pp 242 - 251 | - |
| dc.citation.title | 전력전자학회 논문지 | - |
| dc.citation.volume | 29 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 242 | - |
| dc.citation.endPage | 251 | - |
| dc.identifier.kciid | ART003087343 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Thyristor AC/AC converter | - |
| dc.subject.keywordAuthor | Harmonic current reduction | - |
| dc.subject.keywordAuthor | Infrared radiation drying | - |
| dc.subject.keywordAuthor | PLL algorithm | - |
| dc.subject.keywordAuthor | d-q based power calculation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.