Cited 0 time in
수소 스테이션 전용 PCHE형 고성능 열교환기의열 해석 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 양영준 | - |
| dc.date.accessioned | 2024-05-08T07:00:20Z | - |
| dc.date.available | 2024-05-08T07:00:20Z | - |
| dc.date.issued | 2024-04 | - |
| dc.identifier.issn | 1229-604X | - |
| dc.identifier.issn | 2508-3805 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/70495 | - |
| dc.description.abstract | The PCHE(Printed Circuit Heat Exchanger)-type heat exchanger, which was fabricated by etching and diffusion bonding, was used to hydrogen station, VHTR(Very High Temperature Reactor), SMR and so on. The hydrogen station equipped with PCHE-type heat exchanger is necessary to inject the hydrogen gas into facilities, for instance, such as HFCV(Hydrogen Fuel Cell Vehicle) and power systems. The purpose of this study is to investigate the thermal characteristics of thin plate of PCHE depending on constraint conditions through numerical analysis. As the results, it showed that thermal stress of thin plate, which was not performed diffusion bonding at all, was larger than that, which was performed perfect diffusion bonding, and its maximum difference was about 3 times. Further it was confirmed that the thermal characteristics of thin plate could be obtained by investigating the heat flux. | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국기계기술학회 | - |
| dc.title | 수소 스테이션 전용 PCHE형 고성능 열교환기의열 해석 연구 | - |
| dc.title.alternative | Study on Thermal Analysis of PCHE-type Heat Exchanger with High Performance for Hydrogen Station | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.17958/ksmt.26.2.202404.279 | - |
| dc.identifier.bibliographicCitation | 한국기계기술학회지, v.26, no.2, pp 279 - 285 | - |
| dc.citation.title | 한국기계기술학회지 | - |
| dc.citation.volume | 26 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 279 | - |
| dc.citation.endPage | 285 | - |
| dc.identifier.kciid | ART003074263 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | PCHE-type heat exchanger | - |
| dc.subject.keywordAuthor | Hydrogen station | - |
| dc.subject.keywordAuthor | Hydrogen gas | - |
| dc.subject.keywordAuthor | Diffusion bonding | - |
| dc.subject.keywordAuthor | Thermal analysis | - |
| dc.subject.keywordAuthor | Constraint condition | - |
| dc.subject.keywordAuthor | 인쇄기판형 열교환기 | - |
| dc.subject.keywordAuthor | 수소스테이션 | - |
| dc.subject.keywordAuthor | 수소 가스 | - |
| dc.subject.keywordAuthor | 확산접합 | - |
| dc.subject.keywordAuthor | 열해석 | - |
| dc.subject.keywordAuthor | 구속조건 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.