Cited 12 time in
Energy retrofit technology for modern and contemporary educational historical buildings considering preservation and utilization aspects
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Haedeun | - |
| dc.contributor.author | Park, Jinyoung | - |
| dc.contributor.author | Kim, Sumin | - |
| dc.contributor.author | Chang, Seong Jin | - |
| dc.date.accessioned | 2024-04-17T01:30:40Z | - |
| dc.date.available | 2024-04-17T01:30:40Z | - |
| dc.date.issued | 2024-06 | - |
| dc.identifier.issn | 2352-4847 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/70299 | - |
| dc.description.abstract | Energy retrofit technology is proposed for achieving continuous and efficient energy utilization in modern educational facilities. To improve the accuracy of diagnosis rather than improving numerical analysis, the building performance evaluation of exterior walls and windows was conducted using on-site measuring equipment. The target building had a substandard domestic performance; therefore, improvement measures were required to use building energy efficiently. We evaluated the energy consumption of the target building through the building energy analysis program DesignBuilder. Energy efficiency and economic benefits of retrofit technologies were evaluated, with seven selected technologies categorized into passive, active, and renewable. Efficient technologies included PV panel, High-efficiency HVAC system, Airtight film, and LED lights. 8 retrofit packages were formulated, considering energy savings, economic viability, and thermal comfort improvements. Among these, the energy-saving package, the package incorporating all technologies, the economically beneficial package, and the conservation package were efficient for energy savings, while the conservation package, the economic benefits, and the passive were economically efficient. energy-saving package was found effective for warm improvement and demonstrated significant improvement in cold thermal comfort conditions. Considering the modern nature of the target building, a comprehensive conservation package was deemed most suitable, offering energy savings, economic benefits, thermal comfort enhancements, and preservation aspects. With a payback period of 4 years and achieving a 41.4% energy saving, it was deemed the optimal choice for the target building. © 2024 The Authors | - |
| dc.format.extent | 13 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier Limited | - |
| dc.title | Energy retrofit technology for modern and contemporary educational historical buildings considering preservation and utilization aspects | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.egyr.2024.03.057 | - |
| dc.identifier.scopusid | 2-s2.0-85189754093 | - |
| dc.identifier.wosid | 001225455500001 | - |
| dc.identifier.bibliographicCitation | Energy Reports, v.11, pp 3995 - 4007 | - |
| dc.citation.title | Energy Reports | - |
| dc.citation.volume | 11 | - |
| dc.citation.startPage | 3995 | - |
| dc.citation.endPage | 4007 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Energy & Fuels | - |
| dc.relation.journalWebOfScienceCategory | Energy & Fuels | - |
| dc.subject.keywordPlus | PERFORMANCE | - |
| dc.subject.keywordPlus | FACILITIES | - |
| dc.subject.keywordPlus | DESIGN | - |
| dc.subject.keywordPlus | DAEGU | - |
| dc.subject.keywordAuthor | Building energy simulation | - |
| dc.subject.keywordAuthor | Economic benefits | - |
| dc.subject.keywordAuthor | Educational historical buildings | - |
| dc.subject.keywordAuthor | Energy retrofit technology | - |
| dc.subject.keywordAuthor | On-site measurements | - |
| dc.subject.keywordAuthor | Thermal comfort | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.