Cited 0 time in
이차전지 슬러리용 파일럿 점도 모니터링 시스템 개발 및 검증
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | You, Hyun Dong | - |
| dc.contributor.author | Choi, Hyeon Woo | - |
| dc.contributor.author | Lee, Byung Min | - |
| dc.contributor.author | Kim, Han Sung | - |
| dc.contributor.author | Hwang, Wook Ryol | - |
| dc.date.accessioned | 2024-03-24T02:31:31Z | - |
| dc.date.available | 2024-03-24T02:31:31Z | - |
| dc.date.issued | 2024-03 | - |
| dc.identifier.issn | 1226-4881 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/70046 | - |
| dc.description.abstract | In the mixing process of lithium-ion secondary battery electrodes, rheological properties of anode and cathode slurries influence significantly the electrochemical and thermomechanical behaviors of the final electrode and, among others, the viscosity is the most important property. The slurry viscosity varies with shear rate and, therefore, the measurement of viscosity involves both the measurements of (representative) both shear rate and viscosity. In this study, we developed and validated a pilot-scale in-situ/on-line viscosity monitoring system through a pipe flow system, using the energy-dissipation-rate-based flow quantification technique, by determining the effective viscosity and effective shear rate from the information of the pressure drop and flow rate, respectively. The viscosity measurement results were validated through both numerical and experimental methods. The measured viscosity as a function of the effective shear rate had with less than 10.48% errors in comparison with the rheological data, once the optimized correction factor for the slurry was employed. © 2024 The Korean Society of Mechanical Engineers. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한기계학회 | - |
| dc.title | 이차전지 슬러리용 파일럿 점도 모니터링 시스템 개발 및 검증 | - |
| dc.title.alternative | Development and Validation of a Pilot Viscosity Monitoring System for Secondary Battery Slurries | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3795/KSME-B.2024.48.3.203 | - |
| dc.identifier.scopusid | 2-s2.0-85186987968 | - |
| dc.identifier.bibliographicCitation | Transactions of the KSME, B, v.48, no.3, pp 203 - 210 | - |
| dc.citation.title | Transactions of the KSME, B | - |
| dc.citation.volume | 48 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 203 | - |
| dc.citation.endPage | 210 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART003057808 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | esci | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Effective Shear Rate | - |
| dc.subject.keywordAuthor | Effective Viscosity | - |
| dc.subject.keywordAuthor | Energy Dissipation Rate | - |
| dc.subject.keywordAuthor | Pressure-Driven Flow | - |
| dc.subject.keywordAuthor | Viscosity Measurement | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.