Cited 0 time in
회전식 점도계를 이용한 상업용 증점제의 점도 분석법 검토
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 반영란 | - |
| dc.contributor.author | 정향연 | - |
| dc.contributor.author | 윤소정 | - |
| dc.contributor.author | 박현진 | - |
| dc.contributor.author | 홍성준 | - |
| dc.contributor.author | 조성민 | - |
| dc.contributor.author | 이양봉 | - |
| dc.contributor.author | 신의철 | - |
| dc.date.accessioned | 2024-03-04T09:00:27Z | - |
| dc.date.available | 2024-03-04T09:00:27Z | - |
| dc.date.issued | 2024-02 | - |
| dc.identifier.issn | 0367-6293 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/69769 | - |
| dc.description.abstract | In this study, the viscosity of six food additives used as thickeners (xanthan gum, glucomannan, guar gum, pullulan, locust bean gum, and polyvinyl alcohol) was verified using a Brookfield rotational viscometer. Pullulan was prepared in a 10% aqueous solution, and other samples were prepared in a 1% aqueous solution. The measurements showed that glucomannan had a high viscosity value of >3,000.00 cp, compared to guar gum with >2,500.00 cp and xanthan gum with >1,000.00 cp. Locust bean gum and pullulan had low viscosity values of 110.00 cp and polyvinyl alcohol had low viscosity values of 6.60 cp. All samples were subjected to intra-day and inter-day precision analyses. As a result of cross-validation performed by the institution, similar viscosity values were achieved for each sample. Therefore, this data show that the rotary viscometer can contribute to high precision when measuring viscosity. | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국식품과학회 | - |
| dc.title | 회전식 점도계를 이용한 상업용 증점제의 점도 분석법 검토 | - |
| dc.title.alternative | Review of viscosity analysis of commercial thickeners using a rotational viscometer | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.9721/KJFST.2024.56.1.1 | - |
| dc.identifier.scopusid | 2-s2.0-85186541471 | - |
| dc.identifier.bibliographicCitation | 한국식품과학회지, v.56, no.1, pp 1 - 7 | - |
| dc.citation.title | 한국식품과학회지 | - |
| dc.citation.volume | 56 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 7 | - |
| dc.identifier.kciid | ART003055080 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | thickener | - |
| dc.subject.keywordAuthor | food additives | - |
| dc.subject.keywordAuthor | rotary viscometer | - |
| dc.subject.keywordAuthor | viscosity | - |
| dc.subject.keywordAuthor | method validation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.