| dc.description.abstract | The intention of this study is to provide the basic data to identify the best suitable buildings for implementing hydrothermal energy systems in the South Gyeongsang Province and to develop a methodology for assessing the feasibility of those systems in the selected buildings. A unified dataset was developed by merging two databases, one for water supply pipe networks and the other for buildings, available in six cities. During the initial screening, a limited number of buildings were selected from the prepared dataset based on predetermined criteria such as distance from water source, usage, and cooling and heating load. In the next step, the feasibility of hydrothermal energy was assessed only for candidate buildings by assigning different weights to each factor such as distance from water source (30 %) and cooling and heating load (30 %) as well as tCO2 reduction (40 %). Our findings showed that the theoretical potential of hydrothermal energy for water supply pipes was high in the order of water intake sites in Mulgeum, Namgang, and Changam. While the best candidate buildings, including both public and private ones, were located in the Changwon and Yangsan cities, private buildings were more beneficial in adopting hydrothermal energy systems than public buildings in terms of distance from water source and cooling and heating load. The feasibility assessment from candidate buildings also demonstrated that hydrothermal energy applications were more effective in private buildings than public buildings, specifically in reducing greenhouse gas emissions, although our self-calculation done automatically by excel macros slightly underestimated all important factors such as energy savings, tCO2 reduction, and cost-benefit than the precise consulting estimate. We believe that the methodology proposed in this study can be used for the pre-screening process of assessing the applicability of renewable energy systems over large areas. | - |
| dc.format.extent | 9 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국환경기술학회 | - |
| dc.title | 건물의 수열에너지 적용성 평가를 위한 방법론 개발 | - |
| dc.title.alternative | Developing a Methodology for Evaluating the Applicability of Hydrothermal Energy in Buildings | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국환경기술학회지, v.24, no.6, pp 425 - 433 | - |
| dc.citation.title | 한국환경기술학회지 | - |
| dc.citation.volume | 24 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 425 | - |
| dc.citation.endPage | 433 | - |
| dc.identifier.kciid | ART003038080 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Hydrothermal energy | - |
| dc.subject.keywordAuthor | Feasibility assessment | - |
| dc.subject.keywordAuthor | Cooling and heating energy | - |
| dc.subject.keywordAuthor | Public and private buildings | - |
| dc.subject.keywordAuthor | Theoretical potential | - |
| dc.subject.keywordAuthor | Excel macros | - |
| dc.subject.keywordAuthor | . | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.