| dc.description.abstract | This study conducted an evaluation of indoor air quality and building energy efficiency in CLT (Cross-Laminated Timber) construction based on the core layer materials used. The results revealed that indoor air quality measurements were lower than the recommended standards for multi-purpose facilities, maintenance criteria, and new residential buildings. Additionally, using DesignBuilder software, thermal performance and building energy consumption were assessed, with PB (Particleboard) demonstrating the lowest energy usage among LW (Larch Wood), PB (Particle Board), and PW (Plywood). Utilizing the building as a dormitory with a PB structure in Central Region 1 would result in the most efficient energy usage, with a consumption rate of 96.9 kWh/m2 . Furthermore, a building energy assessment was conducted for PB with insulation applied, resulting in energy savings ranging from 9.75 to 17.5 kWh/m2 . The dormitory building in Central Region 1 exhibited the most fficient energy utilization at 84.36 kWh/m2 . | - |
| dc.format.extent | 12 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국건축친환경설비학회 | - |
| dc.title | CLT의 코어층 적용 재료에 따른 실내공기질 및 건물에너지 평가 | - |
| dc.title.alternative | Indoor Air Quality and Building Energy Evaluation based on Core Layer Materials Applied in CLT | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국건축친환경설비학회 논문집, v.17, no.6, pp 354 - 365 | - |
| dc.citation.title | 한국건축친환경설비학회 논문집 | - |
| dc.citation.volume | 17 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 354 | - |
| dc.citation.endPage | 365 | - |
| dc.identifier.kciid | ART003035720 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Cross Laminated Timber | - |
| dc.subject.keywordAuthor | Mock-up test | - |
| dc.subject.keywordAuthor | Indoor air quality | - |
| dc.subject.keywordAuthor | Building energy | - |
| dc.subject.keywordAuthor | DesignBuilder | - |
| dc.subject.keywordAuthor | 교차적층목재 | - |
| dc.subject.keywordAuthor | 목업테스트 | - |
| dc.subject.keywordAuthor | 실내공기질 | - |
| dc.subject.keywordAuthor | 건물에너지 | - |
| dc.subject.keywordAuthor | 디자인빌더 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.