dc.description.abstractBackground: Synthetic MRI can provide multiple contrast-weighted brain images with high resolution from a single scan via a 3D sequence using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS). Objective: This study aimed to assess the diagnostic image quality of 3D synthetic MRI using compressed sensing (CS) in clinical practice. Methods: We retrospectively reviewed the imaging data of 47 patients who underwent brain MRI, including 3D synthetic MRI using CS in a single session, between December 2020 and February 2021. Two neuroradiologists independently evaluated the overall image quality, anatomic demarcation, and artifacts for synthetic 3D T1-weighted, T2-weighted, fluid-attenuated inversion recovery (FLAIR), phase-sensitive inversion recovery (PSIR), and double inversion recovery images, using a 5-point Likert scale. The interobserver agreement between the two readers was assessed using percent agreement and weighted κ statistics. Results: The overall image quality of 3D synthetic T1WI and PSIR was good to excellent, with easy or excellent anatomic demarcation and mild or no visible artifact. However, other 3D synthetic MRI-derived images showed insufficient image quality and anatomic demarcation with marked CSF pulsation artifacts. In particular, 3D synthetic FLAIR showed high-signal artifacts on the brain surface. Conclusion: 3D synthetic MRI, at its current status, cannot completely replace conventional brain MRI in daily clinical practice. However, 3D synthetic MRI can achieve scan-time reduction using CS and parallel imaging and may be useful for motion-prone or pediatric patients requiring 3D images where time-efficiency is important. © 2024 The Author(s). Published by Bentham Science Publisher.-
dc.language영어-
dc.language.isoENG-
dc.publisherBentham Science Publishers-
dc.title3D Synthetic Brain MRI with Compressed Sensing: Can It be a Promising way Forward for Daily Neuroimaging?-
dc.typeArticle-
dc.publisher.location아랍에미리트-
dc.identifier.doi10.2174/1573405620666230612125447-
dc.identifier.scopusid2-s2.0-85178373941-
dc.identifier.wosid001444299200001-
dc.identifier.bibliographicCitationCurrent Medical Imaging, v.20-
dc.citation.titleCurrent Medical Imaging-
dc.citation.volume20-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordAuthor3D-QALAS-
dc.subject.keywordAuthorBrain-
dc.subject.keywordAuthorCompressed sensing-
dc.subject.keywordAuthorImage quality-
dc.subject.keywordAuthorMagnetic resonance imaging-
dc.subject.keywordAuthorSynthetic MRI-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Altmetrics

Total Views & Downloads

BROWSE