Cited 0 time in
과전류 조건에 따른 단열 다심관의 수냉각 성능 분석
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이태호 | - |
| dc.contributor.author | 김명준 | - |
| dc.date.accessioned | 2023-11-13T07:43:39Z | - |
| dc.date.available | 2023-11-13T07:43:39Z | - |
| dc.date.issued | 2023-10 | - |
| dc.identifier.issn | 1229-604X | - |
| dc.identifier.issn | 2508-3805 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/68479 | - |
| dc.description.abstract | Recently, the International Maritime Organization is strengthening regulations for ships operating in polar regions. Hence, insulated multi-core tubes as components for vessels operating in extreme cold need to be investigated in various aspects. Furthermore, the demand for research on electric propulsion vessels is also increasingly growing. Thus, to utilize a 4-core insulated multi-core tube with glass wool as insulation, which was previously developed for ships operating in polar regions, as a water-cooled electrical cable, this study conducted an experiment on the temperature change when water at normal temperature 25℃ was supplied as a coolant under the overcurrent varied from 10A to 25A. As a result, the temperature increase of the core in 10A condition was 3.3℃, but it increased to 13.05℃ in the 25A condition. This showed that a temperature difference of approximately 9.75℃ occurred according to the overcurrent load. However, the coolant inlet and outlet temperatures were relatively uniform around 1℃ in all conditions. This suggests that increasing the residence time by proper control of the coolant flow in the future could achieve a higher cooling effect. | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국기계기술학회 | - |
| dc.title | 과전류 조건에 따른 단열 다심관의 수냉각 성능 분석 | - |
| dc.title.alternative | Analysis of Water Cooling Performance of Insulated Multi-Core Tube Under Overcurrent Condition | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.17958/ksmt.25.5.202310.668 | - |
| dc.identifier.bibliographicCitation | 한국기계기술학회지, v.25, no.5, pp 668 - 674 | - |
| dc.citation.title | 한국기계기술학회지 | - |
| dc.citation.volume | 25 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 668 | - |
| dc.citation.endPage | 674 | - |
| dc.identifier.kciid | ART003010566 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Insulated multi core tube(단열 다심관) | - |
| dc.subject.keywordAuthor | Glass wool(글라스울) | - |
| dc.subject.keywordAuthor | Over current(과전류) | - |
| dc.subject.keywordAuthor | Electric propulsion ship(전기 추진선) | - |
| dc.subject.keywordAuthor | IMO(국제해사기구) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.